Literature DB >> 12778030

Feasibility of transesophageal echocardiography with a ten-French monoplane probe.

Alexander N Orsini1, Theodore J Kolias, Katherine R Strelich, William F Armstrong.   

Abstract

OBJECTIVES: We examined the feasibility of transesophageal echocardiography (TEE) using a 10F monoplane probe developed for intracardiac ultrasound (AcuNav, Acuson/Siemens, Mountain View, Calif).
BACKGROUND: Traditional TEE uses a 10- to 12-mm-diameter probe, and conscious sedation is customary to minimize patient discomfort. Because of its small size (3.2-mm diameter), the 10F monoplane probe can be inserted into the esophagus using only topical anesthesia. This provides the potential for a more easily tolerated examination.
METHODS: A total of 20 patients underwent a comprehensive TEE using an adult multiplane probe. Immediately afterward, the 10F monoplane probe was inserted into the esophagus and a targeted examination completed. The 10F monoplane studies were blindly reviewed by 3 observers for the study indication and for 16 diagnostic elements. These were graded against an expert's review of standard TEE.
RESULTS: The 10F monoplane probe was well tolerated in all patients. Observers A, B, and C answered the clinical question in 80%, 85%, and 100%, respectively, with the 10F probe. The percentage of clinical elements deemed evaluable was 71%, 78%, and 80%, respectively. Limitations included incomplete visualization of the mitral valve and a systematic underestimation of the severity of valve regurgitation.
CONCLUSIONS: The 10F monoplane probe is safe, well-tolerated, and capable of evaluating many clinical questions. Because of its small size, conscious sedation may not be necessary. It may be useful for targeted evaluations, for monitoring invasive procedures, or for intermediate or long-term monitoring in an intensive care department.

Entities:  

Mesh:

Year:  2003        PMID: 12778030     DOI: 10.1016/s0894-7317(03)00177-9

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  3 in total

1.  Transoesophageal ultrasonography: a new approach to imaging the thoracic aorta.

Authors:  J B Chambers; P R Taylor; J F Reidy; C Woods; S J Carter; T S Padayachee
Journal:  Heart       Date:  2005-02       Impact factor: 5.994

2.  Intraoperative transesophageal echocardiogram using an intracardiac ultrasound catheter in a congenital heart surgery: a case report.

Authors:  P Costa; C Moura; J C Areias; A R Sousa
Journal:  Pediatr Cardiol       Date:  2012-08-02       Impact factor: 1.655

Review 3.  Intracardiac echocardiography in congenital heart disease.

Authors:  Piers C A Barker
Journal:  J Cardiovasc Transl Res       Date:  2009-01-23       Impact factor: 4.132

  3 in total