Literature DB >> 12776866

Clinical and electrophysiologic predictors of ventricular tachyarrhythmia recurrence in patients with implantable cardioverter defibrillators.

Anne M Gillis1, Robert S Sheldon, D George Wyse, Henry J Duff, Margaret R Cassidy, L Brent Mitchell.   

Abstract

INTRODUCTION: Not all patients experience recurrent sustained ventricular tachyarrhythmias after placement of an implantable cardioverter defibrillator (ICD). We evaluated the clinical and electrophysiologic predictors of ventricular tachycardia (VT) and ventricular fibrillation (VF) recurrence following ICD implantation. METHODS AND
RESULTS: Consecutive patients (n = 133) underwent 4 +/- 3 serial electrophysiologic studies (EPS) over 50 +/- 26 months following ICD implantation. Sustained VT/VF could always be induced during follow-up EPS in 49 patients; sustained VT/VF was sometimes induced during follow-up EPS in 47 patients; and sustained VT/VF could never be induced during follow-up EPS in 37 patients. Spontaneous VT/VF requiring ICD therapy occurred in 107 patients during follow-up. Patients with sustained VT/VF that was always inducible or sometimes inducible during follow-up experienced more frequent episodes of VT/VF following ICD implant (20.5, 95% CI 12.7-33.0; and 17.8, 95% CI 11.3-28.1 episodes/patient respectively; vs 3.0, 95% CI 2.0-4.6 episodes/patient for patients with VT/VF never induced, P < 0.001). Inducibility of sustained VT/VF post-ICD implant (P < 0.001) and sustained VT as the presenting arrhythmia (P = 0.02) were independent predictors of spontaneous VT/VF recurrence.
CONCLUSION: Reproducibly inducible VT/VF following ICD implantation predicts a high probability of VT/VF recurrence and identifies a cohort of patients who experience frequent episodes of VT/VF over time. Persistent noninducibility of sustained VT/VF identifies a group of patients who experience no or very few episodes of VT/VF recurrence.

Entities:  

Mesh:

Year:  2003        PMID: 12776866     DOI: 10.1046/j.1540-8167.2003.02328.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  2 in total

1.  Sudden cardiac death: time to make a difference: Pro ICD.

Authors:  M J Schalij; L van Erven
Journal:  Neth Heart J       Date:  2006-12       Impact factor: 2.380

2.  The prediction of ICD therapy in multicenter automatic defibrillator implantation trial (MADIT) II like patients: a retrospective analysis.

Authors:  Marco Budeus; Nico Reinsch; Heinrich Wieneke; Stefan Sack; Raimund Erbel
Journal:  Indian Pacing Electrophysiol J       Date:  2008-04-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.