Literature DB >> 12775008

Cleaning efficiency of nickel-titanium GT and .04 rotary files when used in a torque-controlled rotary handpiece.

Calvin B Suffridge1, Gary R Hartwell, Thomas L Walker.   

Abstract

This study determined if the cleaning efficiency of nickel-titanium rotary files in an endodontic electric handpiece using a no-torque control setting was superior to that obtained when using the torque-control feature. Fifty extracted human anterior teeth with straight canals were divided into two groups of 20 and two control groups of 5. Canals were instrumented with GT and .04 ProFile nickel-titanium files until a size 35 advanced to working length. Samples were sectioned and the apical 6 mm of the canal was photographed (x20) and projected onto a 3- x 4-foot grid with squares measuring 0.5 inches each. Total debris was the percentage of the number of squares containing debris versus the total number of squares. The teeth in the torque-controlled group showed an average of 24.99% debris versus 15.55% for the teeth in the no-torque group. The difference was not statistically significant; therefore, no difference can be said to exist between the two torque settings in terms of cleaning efficiency.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12775008     DOI: 10.1097/00004770-200305000-00007

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  4 in total

1.  Comparative evaluation of instrumentation timing and cleaning efficacy in extracted primary molars using manual and NiTi rotary technique - Invitro study.

Authors:  Rachita Mehlawat; Rishabh Kapoor; Kapil Gandhi; Dipanshu Kumar; Ritika Malhotra; Shilpa Ahuja
Journal:  J Oral Biol Craniofac Res       Date:  2019-03-17

2.  Histological analysis of cleaning efficacy of hand and rotary instruments in the apical third of the root canal: A comparative study.

Authors:  Ashtha Arya; Dildeep Bali; Mandeep S Grewal
Journal:  J Conserv Dent       Date:  2011-07

3.  A scanning electron microscope study on the effect of an experimental irrigation solution on smear layer removal.

Authors:  Vahid Zand; Hadi Mokhtari; Mehrdad Lotfi; Saeed Rahimi; Aydin Sohrabi; Sina Badamchi Zadeh; Hanieh Mojaver Kahnamooie; Pardis Tehranchi
Journal:  Iran Endod J       Date:  2014-03-08

4.  Microscopic evaluation of cleaning efficiency of three different nickel-titanium rotary instruments.

Authors:  Maryam Bidar; Saeed Moradi; Maryam Forghani; Salma Bidad; Mahtab Azghadi; Shahrzad Rezvani; Shirin Khoynezhad
Journal:  Iran Endod J       Date:  2010-11-15
  4 in total