Literature DB >> 12771827

Polyethylene wear particles in synovial fluid after total knee arthroplasty.

Yukihide Minoda1, Akio Kobayashi, Hiroyoshi Iwaki, Masatsugu Miyaguchi, Yoshinori Kadoya, Hirotsugu Ohashi, Yoshiki Yamano, Kunio Takaoka.   

Abstract

The aims of the current study were to examine polyethylene particles in synovial fluid at an early stage, and to compare a newly introduced medial pivot total knee prosthesis with an established posterior-stabilized total knee prosthesis. Synovial fluid was obtained 1 year after knee arthroplasty from 17 patients with well-functioning prostheses (22 knees, 11 posterior-stabilized prostheses and 11 medial pivot prostheses) under complete sterile conditions. Polyethylene particles were isolated and analyzed by scanning electron microscopy. Particle size (equivalent circle diameter) was 0.78 +/- 0.08 microm (mean +/- standard error) in posterior-stabilized prostheses and 0.67 +/- 0.06 microm in medial pivot prostheses. Particle shape (aspect ratio) was 2.30 +/- 0.22 in posterior-stabilized prostheses and 1.90 +/- 0.16 in medial pivot prostheses. The total numbers of particles were 1.16 +/- 0.57 x 10(8) in posterior-stabilized prostheses and 9.01 +/- 2.95 x 10(6) in medial pivot prostheses. Particles were smaller and rounder in medial pivot prostheses than in posterior-stabilized prostheses, but the differences were not significant. The difference in the common logarithm of particle number was significant. The medial pivot prosthesis generated less wear particles than the posteriorstabilized prosthesis, and these findings may have an impact on the incidence of osteolysis and aseptic loosening.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12771827     DOI: 10.1097/01.blo.0000063122.39522.c2

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  15 in total

1.  Midterm clinical and radiographic results of the medial pivot total knee system.

Authors:  Robert Schmidt; Steven Ogden; J David Blaha; Angelia Alexander; David A Fitch; C Lowry Barnes
Journal:  Int Orthop       Date:  2014-07-11       Impact factor: 3.075

2.  Mid-term clinical results of alumina medial pivot total knee arthroplasty.

Authors:  Takahiro Iida; Yukihide Minoda; Yoshinori Kadoya; Yoshio Matsui; Akio Kobayashi; Hiroyoshi Iwaki; Mitsuhiko Ikebuchi; Taku Yoshida; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-05       Impact factor: 4.342

3.  Patient satisfaction at 2 months following total knee replacement using a second generation medial-pivot system: follow-up of 250 consecutive cases.

Authors:  Philippe P Van Overschelde; David A Fitch
Journal:  Ann Transl Med       Date:  2016-09

4.  No difference between double-high insert and medial-pivot insert in TKA.

Authors:  Kazunari Ishida; Tomoyuki Matsumoto; Nobuhiro Tsumura; Takashi Iwakura; Seiji Kubo; Tetsuhiro Iguchi; Toshihiro Akisue; Kotaro Nishida; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-09       Impact factor: 4.342

5.  Weight of polyethylene wear particles is similar in TKAs with oxidized zirconium and cobalt-chrome prostheses.

Authors:  Young-Hoo Kim; Jun-Shik Kim; Wansoo Huh; Kwang-Hoon Lee
Journal:  Clin Orthop Relat Res       Date:  2009-12-01       Impact factor: 4.176

6.  Changes in microgaps, micromotion, and trabecular strain from interlocked cement-trabecular bone interfaces in total knee replacements with in vivo service.

Authors:  Mark A Miller; Jacklyn R Goodheart; Benjamin Khechen; Dennis Janssen; Kenneth A Mann
Journal:  J Orthop Res       Date:  2015-12-10       Impact factor: 3.494

7.  No difference in in vivo polyethylene wear particles between oxidized zirconium and cobalt-chromium femoral component in total knee arthroplasty.

Authors:  Yukihide Minoda; Kanako Hata; Hiroyoshi Iwaki; Mitsuhiko Ikebuchi; Yusuke Hashimoto; Fumiaki Inori; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-10-20       Impact factor: 4.342

8.  Comparison of in vivo polyethylene wear particles between mobile- and fixed-bearing TKA in the same patients.

Authors:  Yukihide Minoda; Kanako Hata; Mitsuhiko Ikebuchi; Shigekazu Mizokawa; Yoichi Ohta; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-02-04       Impact factor: 4.342

9.  Bio-Environment-Induced Degradation and Failure of Internal Fixation Implants.

Authors:  Yan Zhou; Luke A Perkins; Guodong Wang; Dongsheng Zhou; Hong Liang
Journal:  J Funct Biomater       Date:  2015-10-15

10.  Total Knee Arthroplasty Using a Posterior Cruciate Ligament Sacrificing Medial Pivot Knee: Minimum 5-year Follow-up Results.

Authors:  Yoon-Seok Youm; Sung-Do Cho; Seon-Ho Lee; Hye-Yong Cho
Journal:  Knee Surg Relat Res       Date:  2014-08-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.