| Literature DB >> 12767846 |
A Hernández1, E Martró, C Puzo, L Matas, C Burgués, N Vázquez, J Castella, V Ausina.
Abstract
The mycobactericidal activity of Perasafe (0.26% peracetic acid) was compared with that of Cidex (2% alkaline glutaraldehyde) by an in-use test. Fibreoptic bronchoscopes were artificially contaminated with Mycobacterium tuberculosis or Mycobacterium avium-intracellulare in sputum and, after manual pre-cleaning with a neutral soap, 10 and 20 min disinfection periods were tested. Perasafe was as effective as Cidex, thus requiring a 10 min disinfection period against M. tuberculosis and 20 min against M. avium-intracellulare. The results demonstrate that Perasafe is an effective disinfectant for use in reprocessing fibreoptic bronchoscopes.Entities:
Mesh:
Substances:
Year: 2003 PMID: 12767846 DOI: 10.1016/s0195-6701(03)00072-0
Source DB: PubMed Journal: J Hosp Infect ISSN: 0195-6701 Impact factor: 3.926