The permeability of surgical gloves to seven chemicals commonly used in hospitals.

Erja A Mäkelä1, Sinikka Vainiotalo, Kimmo Peltonen.   

Abstract

Disinfectants may cause adverse effects directly on the skin or systemically by permeating through the skin. In this study breakthrough times were measured for surgical gloves with chemicals which are commonly used in healthcare. Classical methods of analytical chemistry were tailored for the permeation tests, which were carried out according to the European standard EN 374 and the American standard ASTM F739. An exception to the EN 374 standard was made by using a 4 h testing time instead of 8 h. The gloves did not exhibit permeation of potassium hydroxide (45%), sodium hypochlorite (13%) or hydrogen peroxide (30%). Furthermore, neither glutaraldehyde (2%) nor chlorhexidine digluconate (4%) in the commercial disinfectant solutions studied exhibited permeation. Slight permeation of peracetic acid (0.35%) and acetic acid (4%) from a disinfectant agent was observed through single layered natural rubber materials. Clear evidence of formaldehyde permeation was detected through single layered natural rubber gloves, where the ASTM breakthrough times were 17-67 min, but the permeation rates were not high enough for breakthrough to have occurred according to the EN standard. The gloves in this study which offered most protection from chemical permeation were the chloroprene gloves and the thick double layered natural rubber gloves.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12765872     DOI: 10.1093/annhyg/meg044

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  3 in total

Review 1.  Glove permeation of chemicals: The state of the art of current practice, Part 1: Basics and the permeation standards.

Authors:  Sean Banaee; Shane S Que Hee
Journal:  J Occup Environ Hyg       Date:  2019-11-04       Impact factor: 2.155

2.  Double gloving of disposable nitrile gloves exposed to diethylene glycol mono-n-butyl ether.

Authors:  Sayaka Takaku-Pugh; Shane Que Hee
Journal:  J Occup Environ Hyg       Date:  2020-05-29       Impact factor: 2.155

Review 3.  Glove permeation of chemicals: The state of the art of current practice-Part 2. Research emphases on high boiling point compounds and simulating the donned glove environment.

Authors:  Sean Banaee; Shane S Que Hee
Journal:  J Occup Environ Hyg       Date:  2020-03-25       Impact factor: 2.155

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.