Literature DB >> 12765628

Single-injection inulin clearance for routine measurement of glomerular filtration rate in cats.

M Haller1, K Rohner, W Müller, F Reutter, H Binder, W Estelberger, P Arnold.   

Abstract

Glomerular filtration rate (GFR) was determined in 53 cats using an inulin single-injection method. Thirty healthy young adult cats were used to establish normal values. The procedure was also used in 23 cats that were either older than 10 years or had borderline serum creatinine levels. The total clearance was calculated from the decay of the serum inulin concentration after injection of 3000 mg/m(2)body surface area using a two-compartment model. Concomitant inulin and iohexol clearance in nine cats showed excellent correlation between the two methods. Calculated normal values for GFR in 30 healthy cats were 35.9-58.5 (median 46.0) ml/min/m(2)or 2.07-3.69 (median 2.72) ml/min/kg. A few cats with normal creatinine or blood urea nitrogen levels were detected as having reduced GFR and therefore being in a state of early renal dysfunction. The study indicates that single-injection inulin clearance is a valuable tool for routine GFR measurement in cats. An "inulin excretion test" using only one blood sample 3h after the administration of 3000 mg/m(2)body surface area could prove an attractive alternative for the assessment of renal function in daily practice.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12765628     DOI: 10.1016/S1098-612X(03)00005-6

Source DB:  PubMed          Journal:  J Feline Med Surg        ISSN: 1098-612X            Impact factor:   2.015


  3 in total

1.  A Limited Sampling, Simple, and Useful Method for Determination of Glomerular Filtration Rate in Cats by Using a New Accurate HPLC Method to Measure Iohexol Plasmatic Concentrations.

Authors:  Meucci Valentina; Guidi Grazia; Melanie Pierre; Breghi Gloria; Lippi Ilaria
Journal:  J Vet Med       Date:  2013-11-12

2.  A pilot study to assess the feasibility of transcutaneous glomerular filtration rate measurement using fluorescence-labelled sinistrin in dogs and cats.

Authors:  Sarah Steinbach; Nora Krolop; Sellyn Strommer; Zeneida Herrera-Pérez; Stefania Geraci; Jochen Friedemann; Norbert Gretz; Reto Neiger
Journal:  PLoS One       Date:  2014-11-25       Impact factor: 3.240

3.  Assessment of symmetric dimethylarginine as a biomarker of renal function in hyperthyroid cats treated with radioiodine.

Authors:  Eva Buresova; Emmelie Stock; Dominique Paepe; Lisa Stammeleer; Eva Vandermeulen; Pascale Smets; Luc Duchateau; Herve P Lefebvre; Sylvie Daminet
Journal:  J Vet Intern Med       Date:  2019-01-11       Impact factor: 3.333

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.