Literature DB >> 12764258

Management of endoleak after endovascular aneurysm repair: cuffs, coils, and conversion.

Peter L Faries1, Hadley Cadot, Gautam Agarwal, K Craig Kent, Larry H Hollier, Michael L Marin.   

Abstract

OBJECTIVE: The effectiveness of endovascular treatment of abdominal aortic aneurysm (AAA) may be limited by persistent perfusion of the aneurysm sac (endoleak). Endoleak that results in persistent systemic pressurization of the aneurysm or in continued AAA expansion is believed to require treatment to prevent rupture. This report describes the results of three techniques used to treat endoleak.
METHODS: Endovascular repair of AAA was performed in 597 patients between January 1996 and September 2002. Seventy-three endoleaks that required treatment developed in 70 patients (11.7%). These involved the graft attachment site (type I) or the graft junction site (type III) or originated from collateral side-branch vessels (type II) and were associated with an increase in aneurysm size. Endoleak type was confirmed at angiography in all cases. Average time between the initial endovascular procedure and endoleak treatment was 14.5 +/- 5.7 months. The techniques used for endoleak treatment were deployment of an endovascular extension graft or cuff (n = 44), coil embolization (n = 24,) and conversion to conventional open repair (n = 5). Configurations of endovascular grafts in which endoleak developed were bifurcated (n = 44), aortouniiliac (n = 15), and aortoaortic-tube (n = 11). Mean follow-up after endoleak treatment was 24.5 +/- 12.2 months (range, 1-60 months).
RESULTS: Endovascular extension grafts or cuffs were used to treat 41 attachment site endoleaks and 3 graft junction endoleaks, with overall technical success rate of 97%. Embolic coils were used to treat 16 retrograde side-branch endoleaks and 8 attachment site endoleaks, with overall technical success rate of 87%. Conversion to open surgery was performed in 4 patients with attachment site endoleaks and 1 patient with a graft junction site endoleak, and was successful in all cases. After endoleak treatment, aneurysm size decreased (>5 mm) in 38% of patients, stabilized in 58% of patients, and increased (>5 mm) in 4% of patients. Major morbidity occurred in 7.0%, with no perioperative deaths.
CONCLUSIONS: Endovascular extension grafts, coil embolization, and conversion to open surgery each may be used to effectively repair endoleak. Selection of the treatment method used is determined by the anatomic characteristics of the endoleak and the patient's ability to tolerate conventional repair. Conversion to open repair was uniformly successful. Deployment of an extension cuff was successful when complete closure of the endoleak was achieved. Embolic coils were effective for retrograde endoleaks and provided stabilization of AAA size in selected patients with attachment site endoleaks in limited follow-up.

Entities:  

Mesh:

Year:  2003        PMID: 12764258     DOI: 10.1016/s0741-5214(03)00084-3

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  27 in total

1.  Elective endovascular aortic repair conversion for type Ia endoleak is not associated with increased morbidity or mortality compared with primary juxtarenal aneurysm repair.

Authors:  Salvatore T Scali; Michael M McNally; Robert J Feezor; Catherine K Chang; Alyson L Waterman; Scott A Berceli; Thomas S Huber; Adam W Beck
Journal:  J Vasc Surg       Date:  2014-03-27       Impact factor: 4.268

Review 2.  Endoleakage after endovascular treatment of abdominal aortic aneurysms: Diagnosis, significance and treatment.

Authors:  Jafar Golzarian; David Valenti
Journal:  Eur Radiol       Date:  2006-04-11       Impact factor: 5.315

3.  Non-contrast MR imaging for detecting endoleak after abdominal endovascular aortic repair.

Authors:  Elda C Resta; Francesco Secchi; Antonello Giardino; Veronica G Nardella; Giovanni Di Leo; Nicola Flor; Francesco Sardanelli
Journal:  Int J Cardiovasc Imaging       Date:  2012-05-16       Impact factor: 2.357

Review 4.  Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management.

Authors:  Dania Daye; T Gregory Walker
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

5.  The Safety of Using Large Amount (30 cc) of Onyx (Ethylene-vinyl Alcohol Copolymer) for the Treatment of Large Type II Endoleak after Endovascular Repair of Abdominal Aortic Aneurysm.

Authors:  Mohammad Hasan Namazi; Isa Khaheshi; Ali Reza Serati; Mohammad Reza Movahed
Journal:  Int J Angiol       Date:  2016-12-15

6.  Long-term results of aortic banding for complex infrarenal neck anatomy and type I endoleak after endovascular abdominal aortic aneurysm repair.

Authors:  Zvonimir Krajcer; Kathryn G Dougherty; Igor D Gregoric
Journal:  Tex Heart Inst J       Date:  2012

7.  [Endoleaks - when is treatment necessary?].

Authors:  O Dudeck
Journal:  Radiologe       Date:  2013-06       Impact factor: 0.635

Review 8.  Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair.

Authors:  Iosief Abraha; Maria Laura Luchetta; Rita De Florio; Francesco Cozzolino; Giovanni Casazza; Piergiorgio Duca; Basso Parente; Massimiliano Orso; Antonella Germani; Paolo Eusebi; Alessandro Montedori
Journal:  Cochrane Database Syst Rev       Date:  2017-06-09

9.  Strategies of endoleak management following endoluminal treatment of abdominal aortic aneurysms in 95 patients: how, when and why.

Authors:  G Barbiero; A Baratto; F Ferro; J Dall'Acqua; C Fittà; D Miotto
Journal:  Radiol Med       Date:  2008-09-13       Impact factor: 3.469

10.  Percutaneous transabdominal approach for the treatment of endoleaks after endovascular repair of infrarenal abdominal aortic aneurysm.

Authors:  Sun Young Choi; Jong Yun Won; Do Yun Lee; Donghoon Choi; Won-Heum Shim; Kwang-Hun Lee
Journal:  Korean J Radiol       Date:  2009-12-28       Impact factor: 3.500

View more