Literature DB >> 12760987

Can the bispectral index be used to predict seizure time and awakening after electroconvulsive therapy?

Paul F White1, Shivani Rawal, Alejandro Recart, Larry Thornton, Mark Litle, Louis Stool.   

Abstract

UNLABELLED: The electroencephalogram (EEG) bispectral index (BIS) measures the hypnotic component of the anesthetic state and correlates with emergence from general anesthesia. Therefore, we hypothesized that the BIS would be useful in predicting electroconvulsive therapy (ECT)-induced seizure times and awakening from methohexital anesthesia. Twenty-five consenting patients with major depressive disorders underwent 100 maintenance ECT treatments. All patients were premedicated with glycopyrrolate 0.2 mg IV, and anesthesia was induced with methohexital 1 mg/kg IV. The BIS was monitored continuously, and the values were recorded at specific end-points, including before anesthesia (baseline), after the induction of anesthesia (pre-ECT), at the end of ECT (peak), after ECT (suppression), and on awakening (eye opening). The pre-ECT BIS value correlated with the duration of both the motor (r = 0.3) and EEG (r = 0.4) seizure activity (P < 0.05). The peak post-ECT BIS value correlated with the duration of the EEG seizure activity (r = 0.5) (P < 0.05). A positive correlation was also found between the EEG seizure duration and the time to eye opening (r = 0.4) (P < 0.05). However, the BIS values on awakening from methohexital anesthesia varied from 29 to 97 and were <60 in 75% of the cases. We conclude that the BIS value before the ECT stimulus is applied could be useful in predicting the seizure time. However, the BIS values on awakening were highly variable, suggesting that it reflects both the residual depressant effects of methohexital and post-ictal depression. IMPLICATIONS: The bispectral index (BIS) value immediately before the electroconvulsive therapy (ECT) stimulus correlates with the duration of the motor and electroencephalogram (EEG) seizure activity during methohexital anesthesia. In addition, the increase in the BIS value during the ECT-induced seizure was proportional to the duration of EEG seizure activity. However, the BIS value on awakening from anesthesia varied widely, from 29 to 97.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12760987     DOI: 10.1213/01.ane.0000066018.13553.08

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  4 in total

Review 1.  [Anesthesia for electroconvulsive therapy].

Authors:  U Grundmann; S O Schneider
Journal:  Anaesthesist       Date:  2013-04       Impact factor: 1.041

2.  Low bispectral index values following electroconvulsive therapy associated with memory impairment.

Authors:  Toshiya Koitabashi; Tomoko Oyaizu; Takashi Ouchi
Journal:  J Anesth       Date:  2009-05-15       Impact factor: 2.078

3.  Emergence cerebral oxygen desaturation without hemodynamic compromise in pediatric patients.

Authors:  Younsuk Lee; Junyong In; Seunghyun Chung; Kyoung Ok Kim; Jeoung Hyuk Lee; Ki-Hyug Kwon
Journal:  Korean J Anesthesiol       Date:  2010-07-21

4.  The Alaris auditory evoked potential monitor as an indicator of seizure inducibility and duration during electroconvulsive therapy: an observational study.

Authors:  Hsing-Hao Huang; Chun-Yu Wu; Feng-Sheng Lin; Yi-Ping Wang; Wei-Zen Sun; Chih-Peng Lin; Shou-Zen Fan
Journal:  BMC Anesthesiol       Date:  2014-05-13       Impact factor: 2.217

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.