Literature DB >> 12757809

Bias compensated least squares estimate of the center of rotation.

Kjartan Halvorsen1.   

Abstract

It is shown that a recently published least squares method for the estimation of the average center of rotation is biased. Consequently, a correction term is proposed, and an iterative algorithm is derived for finding a bias compensated solution to the least squares problem.The accuracy of the proposed bias compensated least squares method is compared to the previously proposed least squares method by Monte-Carlo simulations. The tests show that the new method gives a substantial improvement in accuracy.

Mesh:

Year:  2003        PMID: 12757809     DOI: 10.1016/s0021-9290(03)00070-8

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  10 in total

1.  Experimental determination of the elbow's center of rotation using the VICON™ optoelectronic motion capture system.

Authors:  Elvire Guerre; Pascale Laronde; Jérôme Cussonneau; Christian Fontaine; Guillaume Wavreille
Journal:  Surg Radiol Anat       Date:  2015-11-20       Impact factor: 1.246

2.  3D inverse dynamics in non-orthonormal segment coordinate system.

Authors:  R Dumas; L Chèze
Journal:  Med Biol Eng Comput       Date:  2007-01-25       Impact factor: 2.602

3.  An X-ray-free method to accurately identify the elbow flexion-extension axis for the placement of a hinged external fixator.

Authors:  Jian Song; Hui Ding; Wei Han; Junqiang Wang; Guangzhi Wang
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-11-03       Impact factor: 2.924

4.  Agonist and antagonist muscle activation in elite athletes: influence of age.

Authors:  Federico Quinzi; Valentina Camomilla; Francesco Felici; Alberto Di Mario; Paola Sbriccoli
Journal:  Eur J Appl Physiol       Date:  2014-09-06       Impact factor: 3.078

5.  Validation of the femoral anteversion measurement method used in imageless navigation.

Authors:  Glen A Turley; Shahbaz M Y Ahmed; Mark A Williams; Damian R Griffin
Journal:  Comput Aided Surg       Date:  2012-06-08

6.  Comparison of two methods for in vivo estimation of the glenohumeral joint rotation center (GH-JRC) of the patients with shoulder hemiarthroplasty.

Authors:  Ali Asadi Nikooyan; Frans C T van der Helm; Peter Westerhoff; Friedmar Graichen; Georg Bergmann; H E J Dirkjan Veeger
Journal:  PLoS One       Date:  2011-03-31       Impact factor: 3.240

7.  Evaluation of functional methods of joint centre determination for quasi-planar movement.

Authors:  Lin Meng; Craig Childs; Arjan Buis
Journal:  PLoS One       Date:  2019-01-17       Impact factor: 3.240

8.  Validation of Novel Relative Orientation and Inertial Sensor-to-Segment Alignment Algorithms for Estimating 3D Hip Joint Angles.

Authors:  Lukas Adamowicz; Reed D Gurchiek; Jonathan Ferri; Anna T Ursiny; Niccolo Fiorentino; Ryan S McGinnis
Journal:  Sensors (Basel)       Date:  2019-11-24       Impact factor: 3.576

9.  Pose2Sim: An End-to-End Workflow for 3D Markerless Sports Kinematics-Part 2: Accuracy.

Authors:  David Pagnon; Mathieu Domalain; Lionel Reveret
Journal:  Sensors (Basel)       Date:  2022-04-01       Impact factor: 3.576

10.  Alignment of the metatarsal heads affects foot inversion/eversion during tiptoe standing on one leg in demi-pointe position: A cross-sectional study on recreational dancers.

Authors:  Akiko Imura; Hiroyuki Nagaki; Takahiro Higuch
Journal:  PLoS One       Date:  2022-10-18       Impact factor: 3.752

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.