Literature DB >> 12757534

Collection of MNCs and progenitor cells by two separators for PBPC transplantation: a randomized crossover trial.

Kazuhiko Ikeda1, Hitoshi Ohto, Kenji Nemoto, Go Yamamoto, Katsuhiko Kato, Takashi Ogata, Tsutomu Shichishima, Yukio Maruyama.   

Abstract

BACKGROUND: Efficient collection of progenitor cells is essential for PBPC transplantation. Two apheresis machines (Amicus, Baxter Healthcare; and Spectra, Gambro BCT, software version 4.7) were compared prospectively by a crossover trial. STUDY DESIGN AND METHODS: Apheresis collections were performed for two consecutive days on patients for autologous and donors for allogeneic PBPC transplantation. The patients and donors, receiving a G-CSF, were randomized into two groups. In Group I, PBPCs were collected by the Amicus on the 1st day and the Spectra on the 2nd day, and the reverse order was used with Group II. A total of 60 apheresis procedures of 30 (16 in Group I and 14 in Group II) among 40 patients and donors enrolled were performed and evaluated.
RESULTS: The nucleated cell counts, MNC counts, CD34+ PBPC counts, and amounts of CFU-GM collected per procedure were similar with the Amicus and the Spectra. On the other hand, the decrease of peripheral blood platelet counts of patients and donors was more prominent from using Spectra than Amicus (p < 0.0001). Components collected by the Amicus had fewer platelets than those collected by the Spectra (p < 0.0001). The efficiencies of collecting nucleated cells, MNCs, and CD34+ PBPCs were not different between the machines (p > 0.05). However, the efficiency of collecting platelets was significantly higher with Spectra than with Amicus (p < 0.0001). The Amicus took longer than the Spectra to process the same volume (p < 0.05).
CONCLUSION: Amicus is superior to Spectra in avoiding apheresis-induced thrombocytopenia caused by platelets contaminating the collected samples. Therefore, the Amicus is useful for patients with thrombocytopenia or with a less-than-normal platelet count.

Entities:  

Mesh:

Year:  2003        PMID: 12757534     DOI: 10.1046/j.1537-2995.2003.00422.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  3 in total

1.  Efficient removal of platelets from peripheral blood progenitor cell products using a novel micro-chip based acoustophoretic platform.

Authors:  Josefina Dykes; Andreas Lenshof; Ing-Britt Åstrand-Grundström; Thomas Laurell; Stefan Scheding
Journal:  PLoS One       Date:  2011-08-09       Impact factor: 3.240

Review 2.  Hematopoietic stem and progenitor cell harvesting: technical advances and clinical utility.

Authors:  Olivier Hequet
Journal:  J Blood Med       Date:  2015-02-18

3.  Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection.

Authors:  Se Na Lee; Ji Yeon Sohn; Jung Hee Kong; Hyeon Seok Eom; Hyewon Lee; Sun Young Kong
Journal:  Ann Lab Med       Date:  2017-07       Impact factor: 3.464

  3 in total