BACKGROUND AND OBJECTIVES: A study was undertaken to determine plasma quality after specific filtration.
MATERIALS AND METHODS: Seven types of plasma were tested, after filtration of plasma from filtered or non-filtered whole blood. Leucocyte counting was carried out after a 30-fold concentration of the sample. Twenty-nine parameters (including coagulation testing, proteins, coagulation factors and activation markers) were measured before and after filtration, and after 6 months of storage.
RESULTS: After specific plasma filtration, the average residual leucocyte counts were less than 2250/l. In spite of small statistically significant changes in proteins, coagulation factors and complement activation, this study showed that plasma filtration did not alter plasma quality. After 6 months of storage at -30 degrees C, factor VIII recovery varied between 91 and 109%. Haemostasis parameters and activation markers remained within the normal range.
CONCLUSIONS: Specific plasma filtration reduced the leucocyte number to < 104 leucocytes/l. The quality of plasma was not altered by the additional step of specific plasma filtration.

Mesh:

Substances:

Year:  2003        PMID: 12757505     DOI: 10.1046/j.1423-0410.2003.00288.x

Source DB:  PubMed          Journal:  Vox Sang        ISSN: 0042-9007            Impact factor:   2.144


  4 in total

1.  Recommendations from the Tuscan Transfusion System on the appropriate use of solvent/detergent-inactivated fresh-frozen plasma.

Authors:  Giancarlo Maria Liumbruno; Maria Laura Sodini; Giuliano Grazzini
Journal:  Blood Transfus       Date:  2008-01       Impact factor: 3.443

2.  Main Properties of the THERAFLEX MB-Plasma System for Pathogen Reduction.

Authors:  Jerard Seghatchian; Wilhelm G Struff; Stefan Reichenberg
Journal:  Transfus Med Hemother       Date:  2011-01-27       Impact factor: 3.747

3.  Evaluation of the plasma quality after filtration.

Authors:  M Mahmoodian Shooshtari; K Mousavi Hosseini
Journal:  Daru       Date:  2010       Impact factor: 3.117

4.  Impacts of leukocyte filtration and irradiation on coagulation factors in fresh frozen plasma.

Authors:  Dai-Yu Li; Hong-Wei Zhang; Qing-Zhen Feng; Hua Zhao
Journal:  Exp Ther Med       Date:  2014-12-10       Impact factor: 2.447

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.