Literature DB >> 12757468

Contrast-enhanced magnetic resonance angiography: development and optimization of techniques for paramagnetic and hyperpolarized contrast media.

Jonas Svensson1.   

Abstract

Contrast-enhanced magnetic resonance angiography (CE-MRA) is a diagnostic method for imaging of vascular structures based on nuclear magnetic resonance. Vascular enhancement is achieved by injection of a contrast medium (CM). Studies were performed using two different types of CM: conventional paramagnetic CM, and a new type of CM based on hyperpolarized (HP) nuclei. The effects of varying CM concentration with time during image acquisition were studied by means of computer simulations using two different models. It was shown that a rapid concentration variation during encoding of the central parts of k-space could result in signal loss and severe image artifacts. The results were confirmed qualitatively with phantom experiments. A postprocessing method was developed to address problems with simultaneous enhancement of arteries and veins in CE-MRA of the lower extremities. The method was based on the difference in flow-induced phase in the two vessel types. Evaluation of the method was performed with flow phantom measurements and with CE-MRA in two volunteers using standard pulse sequences. The flow-induced phase in the vessels of interest was sufficient to distinguish arteries from veins in the superior-inferior direction. Using this method, the venous enhancement could be extinguished. The possibility of using HP nuclei as CM for CE-MRA was evaluated. Signal expressions for a flow of HP CM imaged with a gradient echo sequence were derived. These signal expressions were confirmed in phantom experiments using HP 129Xe dissolved in ethanol. Studies were also performed with a new CM based on HP 13C. The CM had very long relaxation times (T1, in vivo/T2, in vivo approximately 38/1.3 s). The long relaxation times were utilized in imaging with a fully balanced steady-state free precession pulse sequence (trueFISP), where the optimal flip angle was found to be 180 degrees. CE-MRA with the 13C-based CM in rats resulted in images with high vascular SNR (approximately 500). CE-MRA is a useful clinical tool for diagnosing vascular disease. With the development of new contrast media, based on hyperpolarized nuclei for example, there is a potential for further improvement in the signal levels that can be achieved, enabling a standard of imaging of vessels that is not possible today.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12757468     DOI: 10.1034/j.1600-0455.44.s.429.1.x

Source DB:  PubMed          Journal:  Acta Radiol Suppl        ISSN: 0365-5954


  4 in total

1.  Ultra-fast three dimensional imaging of hyperpolarized 13C in vivo.

Authors:  P Bhattacharya; K Harris; A P Lin; M Mansson; V A Norton; W H Perman; D P Weitekamp; B D Ross
Journal:  MAGMA       Date:  2005-11-23       Impact factor: 2.310

Review 2.  Hyperpolarized carbon-13 magnetic resonance spectroscopic imaging: a clinical tool for studying tumour metabolism.

Authors:  Fulvio Zaccagna; James T Grist; Surrin S Deen; Ramona Woitek; Laura Mt Lechermann; Mary A McLean; Bristi Basu; Ferdia A Gallagher
Journal:  Br J Radiol       Date:  2018-01-19       Impact factor: 3.039

Review 3.  Chemistry and biochemistry of 13C hyperpolarized magnetic resonance using dynamic nuclear polarization.

Authors:  Kayvan R Keshari; David M Wilson
Journal:  Chem Soc Rev       Date:  2013-12-20       Impact factor: 54.564

4.  Size and PEG Length-Controlled PEGylated Monocrystalline Superparamagnetic Iron Oxide Nanocomposite for MRI Contrast Agent.

Authors:  Li-Hua Deng; Hai Jiang; Fu-Lin Lu; Han-Wei Wang; Yu Pu; Chang-Qiang Wu; Hong-Jie Tang; Ye Xu; Tian-Wu Chen; Jiang Zhu; Cheng-Yi Shen; Xiao-Ming Zhang
Journal:  Int J Nanomedicine       Date:  2021-01-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.