Literature DB >> 12755536

Evaluation of simethicone-coated cellulose as a negative oral contrast agent for abdominal CT.

Dushyant V Sahani1, Kartik S Jhaveri, Roy V D'souza, Jose C Varghese, Elkan Halpern, Mukesh G Harisinghani, Peter F Hahn, Sanjay Saini.   

Abstract

RATIONALE AND
OBJECTIVES: Because of the increased clinical use of computed tomography (CT) for imaging the abdominal vasculature and urinary tract, there is a need for negative contrast agents. The authors undertook this study to assess the suitability of simethicone-coated cellulose (SCC), which is approved for use as an oral contrast agent in sonography, for use as a negative oral contrast agent in abdominal CT.
MATERIALS AND METHODS: This prospective study involved 40 adult patients scheduled to undergo abdominal CT for the evaluation of hematuria. Prior to scanning, 20 subjects received 800 mL of SCC and 20 received 800 mL of water as an oral contrast agent. Imaging was performed with a multi-detector row helical scanner in two phases, according to the abdominal CT protocol used for hematuria evaluation at the authors' institution. The first, "early" phase began an average of 15 minutes after the ingestion of contrast material; the second, "late" phase began an average of 45 minutes after the ingestion of contrast material. Blinded analysis was performed by three abdominal radiologists separately, using a three-point scale (0 = poor, 1 = acceptable, 2 = excellent) to assess the effectiveness of SCC for marking the proximal, middle, and distal small bowel. Average scores for enhancement with SCC and with water were obtained and compared. Statistical analysis was performed with a Wilcoxon signed-rank test.
RESULTS: SCC was assigned higher mean scores than water for enhancement in each segment of the bowel, both on early-phase images (0.8-1.35 for SCC vs 0.6-1.1 for water) and on late-phase images (1.1-1.4 vs 0.81-0.96). Bowel marking with SCC, particularly in the jejunum and ileum, also was rated better than that with water in a high percentage of patients. The differences between the scores for water and for SCC, however, were not statistically significant (P > .05).
CONCLUSION: SCC is effective as a negative oral contrast agent for small bowel marking at CT.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12755536     DOI: 10.1016/s1076-6332(03)80057-0

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  6 in total

Review 1.  Use of positive oral contrast agents in abdominopelvic computed tomography for blunt abdominal injury: meta-analysis and systematic review.

Authors:  Chau Hung Lee; Benjamin Haaland; Arul Earnest; Cher Heng Tan
Journal:  Eur Radiol       Date:  2013-04-27       Impact factor: 5.315

2.  Evaluation of the effects of oral water and low-density barium sulphate suspension on bowel appearance on FDG-PET/CT.

Authors:  Michael A Blake; Bindu N Setty; Carmel G Cronin; Mannudeep Kalra; Nagaraj Setty Holalkere; Alan J Fischman; Peter R Mueller; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2009-08-13       Impact factor: 5.315

3.  Gastrointestinal tract labeling for MDCT of abdomen: comparison of low density barium and low density barium in combination with water.

Authors:  Kavita Gulati; Zarine K Shah; Nisha Sainani; Raul Uppot; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2008-01-08       Impact factor: 5.315

4.  Improving quality of colonoscopy by adding simethicone to sodium phosphate bowel preparation.

Authors:  Sasinee Tongprasert; Abhasnee Sobhonslidsuk; Sasivimol Rattanasiri
Journal:  World J Gastroenterol       Date:  2009-06-28       Impact factor: 5.742

5.  Efficacy of a Product Containing Xyloglucan and Pea Protein on Intestinal Barrier Function in a Partial Restraint Stress Animal Model.

Authors:  Sarah Adriana Scuderi; Giovanna Casili; Marika Lanza; Alessio Ardizzone; Luca Pantaleo; Michela Campolo; Irene Paterniti; Laura Cucinotta; Salvatore Cuzzocrea; Emanuela Esposito
Journal:  Int J Mol Sci       Date:  2022-02-18       Impact factor: 5.923

6.  Utility of negative oral contrast (milk with 4% fat) in PET-CT studies.

Authors:  Samuel Aban Meyer; Sachin Gawde
Journal:  Indian J Nucl Med       Date:  2012-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.