| Literature DB >> 12752940 |
H G Neto1, M S M Cândido, A L R Júnior, P P N S Garcia.
Abstract
The present study was designed to analyse the average depth of the microporosity of a nickel-chromium (Ni-Cr) system alloy (Verabond II). The metal surface was subject to one of the following surface treatment: (i) Electrolytic etching in nitric acid 0.5 N at a current density of 250 mA cm(-2); (ii) chemical etching with CG-Etch etchant; and (iii) Sandblasting with alumina particles 50 microm. Half of the samples were polished before the surface treatments. The depth of porosity was measured through photomicrographs (500x) with a profilometer, and the data were statistically analysed using an analysis of variance (anova) followed by Tukey's test. The conclusions were (i) Differents surface treatment of the Ni-Cr system alloy lead to different depths of microporosity; (ii) The greatest depth of porosity was observed in non-polished alloy; (iii) The greatest and identical depth of microporosity was observed following electrolytic etching and chemical etching; (iv) The least and identical depth of microporosity was observed with chemical etching and sandblasting with alumina particles 50 microm, and (v) Chemical etching showed an intermediary depth.Entities:
Mesh:
Substances:
Year: 2003 PMID: 12752940 DOI: 10.1046/j.1365-2842.2003.01102.x
Source DB: PubMed Journal: J Oral Rehabil ISSN: 0305-182X Impact factor: 3.837