Literature DB >> 12752927

Stress distribution of abutments and base displacement with precision attachment- and telescopic crown-retained removable partial dentures.

M Saito1, Y Miura, K Notani, T Kawasaki.   

Abstract

Five types of removable partial dentures (two attachment dentures, two telescopic dentures and one clasp denture) were designed. The two attachment dentures were retained by the rigid-precision attachments with or without a stabilizing arm, and the two telescope dentures were retained with cone telescope crowns with or without cross-arch stabilization. The stresses acting on abutment teeth and denture bases and the movements of denture bases were investigated, and the influences of denture design were clarified. The stress acting on a terminal abutment tooth retained by a rigid-precision attachment or cone telescopic crown was larger than that acting on a terminal abutment tooth retained by a clasp. The attachment dentures tended to concentrate more stress at the terminal abutment tooth than did the telescopic dentures. The stress of denture base of an attachment denture and a telescopic denture was less than that of a clasp denture. There was no difference between the stresses of attachment and telescopic dentures. The displacement of the denture base tended to be less when the denture was designed with a rigid connection for the retainer and with cross-arch stabilization.

Mesh:

Year:  2003        PMID: 12752927     DOI: 10.1046/j.1365-2842.2003.01092.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  7 in total

1.  Implant Supported Distal Extension over Denture Retained by Two Types of Attachments. A Comparative Radiographic Study by Cone Beam Computed Tomography.

Authors:  Ahmed I Mahrous; Hussien A Aldawash; Tarek A Soliman; Fahad H Banasr; Ahmed Abdelwahed
Journal:  J Int Oral Health       Date:  2015-05

2.  Telescopic Overdenture and Implant Supported Fixed Partial Denture: A Pragmatic Treatment Approach.

Authors:  Doğu Ömür Dede; M Cenk Durmuşlar; Onur Şahın; Ayşegül Köroğlu; Özer İşısağ
Journal:  Case Rep Dent       Date:  2015-05-27

3.  Telescopic overdenture: Perio-prostho concern for advanced periodontitis.

Authors:  Roma Goswami; Puneet Mahajan; Amit Siwach; Ankur Gupta
Journal:  Contemp Clin Dent       Date:  2013-07

4.  In vitro retention force measurement for three different attachment systems for implant-retained overdenture.

Authors:  Kareem Mohammed Reda; Ibrahim Ramadan El-Torky; Mohamed Nabeel El-Gendy
Journal:  J Indian Prosthodont Soc       Date:  2016 Oct-Dec

5.  Comparison of using different bridge prosthetic designs for partial defect restoration through mathematical modeling.

Authors:  Oksana Styranivska; Nataliia Kliuchkovska; Nataliya Mykyyevych
Journal:  Eur J Dent       Date:  2017 Jul-Sep

Review 6.  Medication-related osteonecrosis of the jaw: Prosthodontic considerations.

Authors:  Islam E Ali; Yuka Sumita
Journal:  Jpn Dent Sci Rev       Date:  2021-12-18

7.  Aesthetic and Occlusal Rehabilitation Using a Telescopic Denture.

Authors:  Ang Yee; Goo Chui Ling
Journal:  Cureus       Date:  2020-03-25
  7 in total