Aortoenteric fistula due to endoleak coil embolization after endovascular AAA repair.

Daniel J Bertges1, Edward R Villella, Michel S Makaroun.   

Abstract

PURPOSE: To report a late complication associated with embolization coils used to treat an endoleak after endovascular abdominal aortic aneurysm (AAA) repair. CASE REPORT: A 79-year-old man with a 5.8-cm AAA underwent endovascular repair with an Ancure graft in 1997. A persistent type I endoleak was identified on serial postoperative computed tomographic scans. Three transarterial coil embolization procedures were performed to treat an endoleak from the proximal and right distal attachment sites with outflow by the inferior mesenteric and lumbar arteries. Coil embolization was ultimately successful in sealing the endoleak, and the AAA decreased in size. Four years later, the patient developed an aortoenteric fistula due to erosion of the metallic embolization coils into the duodenum. The endograft was explanted and an extra-anatomical bypass inserted.
CONCLUSIONS: Coil embolization to treat endoleaks can, on rare occasions, be the cause of aortoenteric fistula. Lifelong follow-up of stent-graft patients is required.

Entities:  

Mesh:

Year:  2003        PMID: 12751944     DOI: 10.1177/152660280301000125

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  5 in total

1.  A 72-year-old man with intermittent fever, anemia and a history of coronary and peripheral artery disease.

Authors:  Stefano Del Pace; Andrea Savino; Raffaele Rasoini; Camilla Alderighi; Manlio Acquafresca; Alessandro Alessi Innocenti; Carlo Pratesi; Gian Franco Gensini
Journal:  Intern Emerg Med       Date:  2010-06-05       Impact factor: 3.397

2.  Secondary Aorto-enteric Fistula and Type II Endoleak Five Years after Endovascular Abdominal Aortic Aneurysm Repair.

Authors:  Yojiro Koda; Hirohisa Murakami; Masato Yoshida; Hitoshi Matsuda; Nobuhiko Mukohara
Journal:  EJVES Short Rep       Date:  2019-05-16

3.  Coil migration after transarterial coil embolization of a splenic artery pseudoaneurysm.

Authors:  Bezawit D Tekola; David M Arner; Brian W Behm
Journal:  Case Rep Gastroenterol       Date:  2013-11-19

Review 4.  Aortoenteric fistula as a complication of open reconstruction and endovascular repair of abdominal aorta.

Authors:  Marek Tagowski; Hendryk Vieweg; Christian Wissgott; Reimer Andresen
Journal:  Radiol Res Pract       Date:  2014-09-14

5.  Migrated embolization coil causes intestinal obstruction.

Authors:  W Preston Hewgley; David L Webb; H Edward Garrett
Journal:  J Vasc Surg Cases Innov Tech       Date:  2017-12-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.