Literature DB >> 12747588

Molecular beacons as diagnostic tools: technology and applications.

Klara Abravaya1, Jeffrey Huff, Ron Marshall, Barbara Merchant, Carolyn Mullen, George Schneider, John Robinson.   

Abstract

Molecular beacons are single-stranded, fluorophore-labeled nucleic acid probes that are capable of generating a fluorescent signal in the presence of target, but are dark in the absence of target. Molecular beacons allow multiplex detection of PCR products in real time in a homogeneous assay format. Real time detection is inherently quantitative and affords a greater dynamic range than end-point detection methods. Reactions in a homogeneous assay format are sealed before amplification takes place, providing improved contamination control. A single cycler/reader instrument, coupled with automated sample preparation, results in higher throughput and greater ease of use. A multiplex qualitative assay that detects Chlamydia trachomatis and Neisseria gonorrhoeae, along with an internal control, has been developed. High specificity is achieved through careful selection of primers, probes and assay conditions. Quantitative HIV, HCV, and HBV viral load assays, with sensitivities of 50 copies/ml, 20 IU/ml, and 50 copies/ml, respectively, are achievable. The viral load assays are designed to quantitate all subtype and genotype specimens equivalently. A molecular beacon assay has been designed to detect a single nucleotide polymorphism in the beta2 adrenergic receptor gene.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12747588     DOI: 10.1515/CCLM.2003.070

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  15 in total

1.  An inexpensive gel electrophoresis-based polymerase chain reaction method for quantifying mRNA levels.

Authors:  William D Bradford; Laty Cahoon; Sara R Freel; Laura L Mays Hoopes; Todd T Eckdahl
Journal:  Cell Biol Educ       Date:  2005

2.  Coupling molecular beacons to barcoded metal nanowires for multiplexed, sealed chamber DNA bioassays.

Authors:  Rebecca L Stoermer; Kristin B Cederquist; Sean K McFarland; Michael Y Sha; Sharron G Penn; Christine D Keating
Journal:  J Am Chem Soc       Date:  2006-12-27       Impact factor: 15.419

3.  A single-tube nucleic acid extraction, amplification, and detection method using aluminum oxide.

Authors:  Shale Dames; L Kathryn Bromley; Mark Herrmann; Marc Elgort; Maria Erali; Roger Smith; Karl V Voelkerding
Journal:  J Mol Diagn       Date:  2006-02       Impact factor: 5.568

4.  Live-cell characterization and analysis of a clinical isolate of bovine respiratory syncytial virus, using molecular beacons.

Authors:  Philip Santangelo; Nitin Nitin; Leslie LaConte; Amelia Woolums; Gang Bao
Journal:  J Virol       Date:  2006-01       Impact factor: 5.103

Review 5.  Hepatitis B virus taxonomy and hepatitis B virus genotypes.

Authors:  Stephan Schaefer
Journal:  World J Gastroenterol       Date:  2007-01-07       Impact factor: 5.742

6.  The laboratory diagnosis of Neisseria gonorrhoeae.

Authors:  Lai-King Ng; Irene E Martin
Journal:  Can J Infect Dis Med Microbiol       Date:  2005-01       Impact factor: 2.471

Review 7.  Molecular methods for diagnosis of viral encephalitis.

Authors:  Roberta L Debiasi; Kenneth L Tyler
Journal:  Clin Microbiol Rev       Date:  2004-10       Impact factor: 26.132

8.  External quality assessment for detection of Chlamydia trachomatis.

Authors:  V J Chalker; H Vaughan; P Patel; A Rossouw; H Seyedzadeh; K Gerrard; V L A James
Journal:  J Clin Microbiol       Date:  2005-03       Impact factor: 5.948

Review 9.  Basic principles of fluorescence and energy transfer applied to real-time PCR.

Authors:  Larry E Morrison
Journal:  Mol Biotechnol       Date:  2010-02       Impact factor: 2.695

10.  Real-time PCR assay using molecular beacon for quantitation of hepatitis B virus DNA.

Authors:  Simon Siu-Man Sum; Danny Ka-Ho Wong; Man-Fung Yuen; He-Jun Yuan; Jian Yu; Ching-Lung Lai; David Ho; Linqi Zhang
Journal:  J Clin Microbiol       Date:  2004-08       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.