Literature DB >> 12743860

[Functional CT imaging: Load-dependent visualization of the subchondral mineralization by means of CT osteoabsorptiometry (CT-OAM)].

U Linsenmaier1, S Kersting, K Schlichtenhorst, R Putz, K J Pfeifer, M Reiser, M Müller-Gerbl.   

Abstract

PURPOSE: Functional computed tomography for visualization and quantification of subchondral bone mineralization using CT osteoabsorptiometry (CT-OAM).
MATERIALS AND METHODS: Tarsometatarsal (TMT) and metatarsophalangeal (MTP) joints of 46 human hallux valgus (HV) specimens were examined (sagittal 1/1/1 mm) on a single slice CT scanner SCT (Somatom Plus 4, Siemens AG). Subchondral bone pixels were segmented and assigned to 10 density value groups (Delta 100 HU, range 200 - 1200 HU) the pixels using volume rendering technique (VRT). The data analysis considered the severity of HV as determined by the radiographically measured HV-angle (a. p. projection).
RESULTS: CT-OAM could generate reproducible densitograms of the distribution pattern of the subchondral bone density for all four joint surfaces (TMT and MTP joints). The bone density localization enables the assignment to different groups, showing a characteristic HV-angle-dependent distribution of the maximum bone mineralization of the load-dependent densitogram (p < 0.001).
CONCLUSION: CT-OAM is a functional CT technique for visualizing and quantifying the distribution of the subchondral bone density, enabling a noninvasive load-dependent assessment of the joint surfaces. Load-dependent densitograms of hallux valgus specimens show a characteristic correlation with an increase of the HV-angle.

Entities:  

Mesh:

Year:  2003        PMID: 12743860     DOI: 10.1055/s-2003-39209

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  4 in total

1.  Intra-operative femoral condylar stress during arthroscopy: an in vivo biomechanical assessment.

Authors:  Rahel B Schmid; Dieter Wirz; Beat Göpfert; Markus P Arnold; Niklaus F Friederich; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-12-11       Impact factor: 4.342

2.  Habitual use of the primate forelimb is reflected in the material properties of subchondral bone in the distal radius.

Authors:  Kristian J Carlson; Biren A Patel
Journal:  J Anat       Date:  2006-06       Impact factor: 2.610

3.  Computed tomography osteoabsorptiometry-based investigation on subchondral bone plate alterations in sacroiliac joint dysfunction.

Authors:  A Poilliot; T Doyle; D Kurosawa; M Toranelli; M Zhang; J Zwirner; M Müller-Gerbl; N Hammer
Journal:  Sci Rep       Date:  2021-04-21       Impact factor: 4.379

4.  Computed tomography osteoabsorptiometry for imaging of degenerative disc disease.

Authors:  Max Hans-Peter Gay; Gordian Born; Arne Mehrkens; Holger Wittig; Magdalena Müller-Gerbl
Journal:  N Am Spine Soc J       Date:  2022-02-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.