Shrinkage stresses in bone cement.

J F Orr1, N J Dunne, J C Quinn.   

Abstract

Shrinkage of bone cement is reported primarily as a consequence of polymerisation, however thermal shrinkage also occurs as a result of its exothermic reaction. It is proposed that the latter effect is important, since it occurs late in the curing cycle at a time when the cement has attained its mechanical properties as a solid, and that residual stresses result. Observations from experiments and literature reports suggest that residual stresses may be sufficient to initiate cracks at the interface between hip replacement stems and cement.A theoretical model has been developed to calculate interference stresses, using thick-walled cylinder theory, on the basis of thermal and total shrinkages. Thermal shrinkage values were calculated using the coefficient of linear thermal expansion of bone cement, while total shrinkages were measured. Moduli of elasticity values were measured for acrylic bone cements ranging from 2.1 to 2.7GPa, as were Poisson's ratio values ranging from 0.38 to 0.46. Theoretical calculation of stresses in a cement mantle, based on assumptions of thermal shrinkage alone, predicted circumferential stresses of 8.4-25.2MPa for cement curing temperatures in the range 60-140 degrees C. It is concluded that cracks observed around hip prosthesis stems in laboratory specimens of bone cement are due to shrinkage and that residual stresses are sufficient to cause crack initiation prior to functional loading.

Mesh:

Substances:

Year:  2003        PMID: 12742733     DOI: 10.1016/s0142-9612(03)00055-3

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  11 in total

1.  Using 'subcement' to simulate the long-term fatigue response of cemented femoral stems in a cadaver model: could a novel preclinical screening test have caught the Exeter matt problem?

Authors:  A Race; M A Miller; K A Mann
Journal:  Proc Inst Mech Eng H       Date:  2010       Impact factor: 1.617

2.  Real time monitoring of the polymerisation of PMMA bone cement using Raman spectroscopy.

Authors:  Christopher P Hagan; John F Orr; Christina A Mitchell; Nicholas J Dunne
Journal:  J Mater Sci Mater Med       Date:  2009-12       Impact factor: 3.896

3.  Optimisation of a two-liquid component pre-filled acrylic bone cement system: a design of experiments approach to optimise cement final properties.

Authors:  James Clements; Gavin Walker; Sreekanth Pentlavalli; Nicholas Dunne
Journal:  J Mater Sci Mater Med       Date:  2014-07-09       Impact factor: 3.896

4.  Real-time synchronous measurement of curing characteristics and polymerization stress in bone cements with a cantilever-beam based instrument.

Authors:  Sri Vikram Palagummi; Forrest A Landis; Martin Y M Chiang
Journal:  Rev Sci Instrum       Date:  2018-03       Impact factor: 1.523

5.  Biomechanical parameters of the BP-enriched bone cement.

Authors:  Łukasz Matuszewski; Grażyna Olchowik; Tomasz Mazurkiewicz; Bartłomiej Kowalczyk; Agata Zdrojewska; Anna Matuszewska; Andrzej Ciszewski; Małgorzata Gospodarek; Iwona Morawik
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-05-14

6.  Shape memory polymer (SMP) scaffolds with improved self-fitting properties.

Authors:  Michaela R Pfau; Kelly G McKinzey; Abigail A Roth; Lance M Graul; Duncan J Maitland; Melissa A Grunlan
Journal:  J Mater Chem B       Date:  2021-04-15       Impact factor: 6.331

7.  Evaluation of a self-fitting, shape memory polymer scaffold in a rabbit calvarial defect model.

Authors:  Michaela R Pfau; Felipe O Beltran; Lindsay N Woodard; Lauren K Dobson; Shelby B Gasson; Andrew B Robbins; Zachary T Lawson; W Brian Saunders; Michael R Moreno; Melissa A Grunlan
Journal:  Acta Biomater       Date:  2021-09-24       Impact factor: 8.947

8.  Smart scaffolds: shape memory polymers (SMPs) in tissue engineering.

Authors:  Michaela R Pfau; Melissa A Grunlan
Journal:  J Mater Chem B       Date:  2021-06-03       Impact factor: 7.571

9.  Experimental and computational approach investigating burst fracture augmentation using PMMA and calcium phosphate cements.

Authors:  Sami M Tarsuslugil; Rochelle M O'Hara; Nicholas J Dunne; Fraser J Buchanan; John F Orr; David C Barton; Ruth K Wilcox
Journal:  Ann Biomed Eng       Date:  2014-01-07       Impact factor: 3.934

10.  Fracture toughness of titanium-cement interfaces: effects of fibers and loading angles.

Authors:  Morshed Khandaker; Khatri Chhetri Utsaha; Tracy Morris
Journal:  Int J Nanomedicine       Date:  2014-04-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.