A new model-based RSA method validated using CAD models and models from reversed engineering.

B L Kaptein1, E R Valstar, B C Stoel, P M Rozing, J H C Reiber.   

Abstract

Roentgen stereophotogrammetric analysis (RSA) was developed to measure micromotion of an orthopaedic implant with respect to its surrounding bone. A disadvantage of conventional RSA is that it requires the implant to be marked with tantalum beads. This disadvantage can potentially be resolved with model-based RSA, whereby a 3D model of the implant is used for matching with the actual images and the assessment of position and rotation of the implant. In this study, a model-based RSA algorithm is presented and validated in phantom experiments. To investigate the influence of the accuracy of the implant models that were used for model-based RSA, we studied both computer aided design (CAD) models as well as models obtained by means of reversed engineering (RE) of the actual implant. The results demonstrate that the RE models provide more accurate results than the CAD models. If these RE models are derived from the very same implant, it is possible to achieve a maximum standard deviation of the error in the migration calculation of 0.06 mm for translations in x- and y-direction and 0.14 mm for the out of plane z-direction, respectively. For rotations about the y-axis, the standard deviation was about 0.1 degrees and for rotations about the x- and z-axis 0.05 degrees. Studies with clinical RSA-radiographs must prove that these results can also be reached in a clinical setting, making model-based RSA a possible alternative for marker-based RSA.

Entities:  

Mesh:

Year:  2003        PMID: 12742455     DOI: 10.1016/s0021-9290(03)00002-2

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  54 in total

1.  Kinematics of a highly congruent mobile-bearing total knee prosthesis.

Authors:  N Wolterbeek; E H Garling; B J A Mertens; H M J van der Linden; R G H H Nelissen; E R Valstar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-17       Impact factor: 4.342

2.  Prosthetic component segmentation with blur compensation: a fast method for 3D fluoroscopy.

Authors:  Giacomo Tarroni; Luca Tersi; Cristiana Corsi; Rita Stagni
Journal:  Med Biol Eng Comput       Date:  2012-03-27       Impact factor: 2.602

3.  Analysis of migration of the Nanos® short-stem hip implant within two years after surgery.

Authors:  Stefan Budde; Frank Seehaus; Michael Schwarze; Christof Hurschler; Thilo Floerkemeier; Henning Windhagen; Yvonne Noll; Max Ettinger; Fritz Thorey
Journal:  Int Orthop       Date:  2015-09-25       Impact factor: 3.075

4.  Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy.

Authors:  Benjamin J Fregly; Haseeb A Rahman; Scott A Banks
Journal:  J Biomech Eng       Date:  2005-08       Impact factor: 2.097

5.  Evaluation of a particle swarm algorithm for biomechanical optimization.

Authors:  Jaco F Schutte; Byung-Il Koh; Jeffrey A Reinbolt; Raphael T Haftka; Alan D George; Benjamin J Fregly
Journal:  J Biomech Eng       Date:  2005-06       Impact factor: 2.097

6.  How do CAD models compare with reverse engineered manufactured components for use in wear analysis?

Authors:  Matthew G Teeter; Douglas D R Naudie; Robert B Bourne; David W Holdsworth
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

7.  A 3D kinematic estimation of knee prosthesis using X-ray projection images: clinical assessment of the improved algorithm for fluoroscopy images.

Authors:  Shunji Hirokawa; M Abrar Hossain; Yuichi Kihara; Shogo Ariyoshi
Journal:  Med Biol Eng Comput       Date:  2008-09-30       Impact factor: 2.602

8.  Accuracy of model-based RSA contour reduction in a typical clinical application.

Authors:  Christof Hurschler; Frank Seehaus; Judith Emmerich; Bart L Kaptein; Henning Windhagen
Journal:  Clin Orthop Relat Res       Date:  2008-05-29       Impact factor: 4.176

9.  Kinematic Accuracy in Tracking Total Wrist Arthroplasty with Biplane Videoradiography using a CT-generated Model.

Authors:  Bardiya Akhbari; Amy Morton; Douglas Moore; Arnold-Peter C Weiss; Scott W Wolfe; Joseph Crisco
Journal:  J Biomech Eng       Date:  2019-02-07       Impact factor: 2.097

10.  Modifications of femoral component design in multi-radius total knee arthroplasty lead to higher lateral posterior femoro-tibial translation.

Authors:  Tilman Pfitzner; Philippe Moewis; Patrick Stein; Heide Boeth; Adam Trepczynski; Philipp von Roth; Georg N Duda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-06-27       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.