Literature DB >> 12740702

Which one is at risk in intraoperative fluoroscopy? Assistant surgeon or orthopaedic surgeon?

Bulent A Tasbas1, M Firat Yagmurlu, Kenan Bayrakci, Ahmet Ucaner, Memduh Heybeli.   

Abstract

BACKGROUND: Orthopaedic surgeons use intraoperative portable fluoroscopy and roentgenography. The present study was an attempt to find out if there is a difference between the occupational radiation exposure to the orthopaedic surgeon and assistant surgeon in the operating room while using intraoperative fluoroscopy or radiographic control and to measure it.
METHODS: During a 3-month period, 107 consecutive operations were monitored for radiation exposure. At monthly intervals, the radiation doses were measured in millirem and recorded. The distance of the orthopaedic surgeon and the assistant surgeon from the X-ray source were noted in every fluoroscopic check. The orthopaedic surgeon was always at a safe distance (more than 90 cm), but the assistant surgeon always stood nearby (10 cm) the X-ray source for positioning of the patient.
RESULTS: The radiation exposure according to the badge on the shoulder was consecutively 3, 4, 3 mrem for the orthopaedic surgeon and 20, 19, 22 mrem for the assistant surgeon. The radiation exposure according to the badges on the anaesthetic machine, in the room and under the apron of the orthopaedic surgeon were all zero, whereas the readings of the badge under the apron of the assistant surgeon were 7, 6, 5 mrem consecutively.
CONCLUSION: Our findings show that although the radiation exposure during orthopaedic operations is below the recommendations of the European Committee on Radiation Protection, there is a higher risk of exposure for the assistant surgeon. It has to be kept in mind that there could be morphological and functional damage in cells exposed to radiation. Therefore, we should continue to use appropriate shielding precautions in view of the unknown long-term risks.

Entities:  

Mesh:

Year:  2003        PMID: 12740702     DOI: 10.1007/s00402-003-0516-x

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  9 in total

1.  [X-ray in trauma and orthopedic surgery. Physical and biological impact, reasonable use, and radiation protection in the operating room].

Authors:  K Dresing
Journal:  Oper Orthop Traumatol       Date:  2011-02       Impact factor: 1.154

2.  [Intraoperative imaging of children and adolescents, for selected fractures and in follow-up after conservative and operative treatment : Part 2 of the results of a nationwide online survey of the Pediatric Traumatology Section of the German Trauma Society].

Authors:  Klaus Dresing; Francisco Fernandez; Peter Schmittenbecher; Kaya Dresing; Peter Strohm; Christopher Spering; Ralf Kraus
Journal:  Unfallchirurg       Date:  2021-12-16       Impact factor: 1.000

3.  Are Indian orthopaedic surgeons aware of the health hazards of radiation exposure? A survey and review on awareness and ways to mitigate them.

Authors:  Binoti Sheth; Arzan Jesia; Rohan Parihar; Rohit Somani; Pankaj Pawar
Journal:  J Clin Orthop Trauma       Date:  2022-08-07

4.  Awareness and attitudes amongst basic surgical trainees regarding radiation in orthopaedic trauma surgery.

Authors:  Fr Khan; Z Ul-Abadin; S Rauf; A Javed
Journal:  Biomed Imaging Interv J       Date:  2010-07-01

5.  Intraoperative Radiation Exposure During Hip Arthroscopy.

Authors:  John P Salvo; Jake Zarah; Zaira S Chaudhry; Kirsten L Poehling-Monaghan
Journal:  Orthop J Sports Med       Date:  2017-07-21

Review 6.  WEIGHT-BEARING COMPUTED TOMOGRAPHY OF THE FOOT AND ANKLE: AN UPDATE AND FUTURE DIRECTIONS.

Authors:  Alexandre Leme Godoy-Santos; Cesar DE Cesar
Journal:  Acta Ortop Bras       Date:  2018 Mar-Apr       Impact factor: 0.513

7.  The Effect of Metal Instrumentation on Patient and Surgical Team Scatter Radiation Exposure Using Mini C-Arm in a Simulated Forearm Fracture Fixation Model.

Authors:  Michael T Groover; Jacob R Hinkley; Daniel E Gerow; H Brent Bamberger; Jennifer Evans; Roland E Gazaille
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2019-06-05

Review 8.  Improved Radiation Exposure Monitoring of Orthopaedic Residents After Institution of a Personalized Lead Protocol.

Authors:  Patrick A Massey; Mitchell E Myers; Ryan D Guedry; Michael T Lowery; Kevin J Perry; R Shane Barton
Journal:  JB JS Open Access       Date:  2022-03-21

9.  Endoscopy-assisted distal locking of an intramedullary nail: A new experimental technique to reduce radiation exposure during distal locking of the intramedullary nails.

Authors:  Serkan Davut; Yunus Doğramacı
Journal:  Jt Dis Relat Surg       Date:  2021-11-19
  9 in total