Literature DB >> 12738150

Persistent fetal occiput posterior position: obstetric outcomes.

Susan E Ponkey1, Amy P Cohen, Linda J Heffner, Ellice Lieberman.   

Abstract

OBJECTIVE: To evaluate the obstetric outcomes associated with persistent occiput posterior position of the fetal head in term laboring patients.
METHODS: We performed a cohort study of 6434 consecutive, term, vertex, laboring nulliparous and multiparous patients, comparing those who delivered infants in the occiput posterior position with those who delivered in the occiput anterior position. We examined maternal demographics, labor and delivery characteristics, and maternal and neonatal outcomes.
RESULTS: The prevalence of persistent occiput posterior position at delivery was 5.5% overall, 7.2% in nulliparas, and 4.0% in multiparas (P <.001). Persistent occiput posterior position was associated with shorter maternal stature and prior cesarean delivery. During labor and delivery, the occiput posterior position was associated with prolonged first and second stages of labor, oxytocin augmentation, use of epidural analgesia, chorioamnionitis, assisted vaginal delivery, third and fourth degree perineal lacerations, cesarean delivery, excessive blood loss, and postpartum infection. Newborns had lower 1-minute Apgar scores, but showed no differences in 5-minute Apgar scores, gestational age, or birth weight.
CONCLUSION: Persistent occiput posterior position is associated with a higher rate of complications during labor and delivery. In our population, the chances that a laboring woman with persistent occiput posterior position will have a spontaneous vaginal delivery are only 26% for nulliparas and 57% for multiparas.

Entities:  

Mesh:

Year:  2003        PMID: 12738150     DOI: 10.1016/s0029-7844(03)00068-1

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  23 in total

1.  Pelvic floor dysfunction 6 years post-anal sphincter tear at the time of vaginal delivery.

Authors:  David Baud; Sylvain Meyer; Yvan Vial; Patrick Hohlfeld; Chahin Achtari
Journal:  Int Urogynecol J       Date:  2011-04-22       Impact factor: 2.894

2.  Epidurals: Do They or Don't They Increase Cesareans?

Authors:  Henci Goer
Journal:  J Perinat Educ       Date:  2015

Review 3.  Evolution of the female pelvis and relationships to pelvic organ prolapse.

Authors:  Megan Schimpf; Paul Tulikangas
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2005-01-15

4.  Ultrasonographic evaluation of the second stage of labor. Predictive parameters for a successful vaginal delivery with or without neuraxial analgesia: a pilot study.

Authors:  Caterina Pizzicaroli; Carlotta Montagnoli; Ilaria Simonelli; Maria Grazia Frigo; Herbert Valensise; Mario Filippo Segatore; Giovanni Larciprete
Journal:  J Ultrasound       Date:  2018-02-28

5.  Effect of intermittent versus continuous bladder catheterization on duration of the second stage of labor among nulliparous women with an epidural: a randomized controlled trial.

Authors:  Abeer Suleiman; Sobhiya Mruwat-Rabah; Gali Garmi; Dorit Dagilayske; Tair Zelichover; Raed Salim
Journal:  Int Urogynecol J       Date:  2017-05-25       Impact factor: 2.894

Review 6.  Primate pelvic anatomy and implications for birth.

Authors:  Wenda Trevathan
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2015-03-05       Impact factor: 6.237

7.  Pelvic floor dysfunction after vaginal delivery: MOODS-a prospective study.

Authors:  Ana Catarina Borges; Natacha Sousa; Rita Sarabando; Catarina Vieira; Bárbara Ribeiro; Paulina Barbosa; Alexandra Miranda; Isabel Reis; Cristina Nogueira-Silva
Journal:  Int Urogynecol J       Date:  2021-09-25       Impact factor: 1.932

8.  Delivery Mode After Manual Rotation of Occiput Posterior Fetal Positions: A Randomized Controlled Trial.

Authors:  Caroline Verhaeghe; Romain Corroenne; Andrew Spiers; Philippe Descamps; Géraldine Gascoin; Pierre-Emmanuel Bouet; Elsa Parot-Schinkel; Guillaume Legendre
Journal:  Obstet Gynecol       Date:  2021-06-01       Impact factor: 7.661

9.  Study protocol. IDUS - Instrumental delivery & ultrasound: a multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery.

Authors:  Deirdre J Murphy; Gerard Burke; Alan A Montgomery; Meenakshi Ramphul
Journal:  BMC Pregnancy Childbirth       Date:  2012-09-13       Impact factor: 3.007

Review 10.  Shaping birth: variation in the birth canal and the importance of inclusive obstetric care.

Authors:  Lia Betti
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2021-05-03       Impact factor: 6.671

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.