Literature DB >> 12735663

A comparison of the end-tidal CO2 measured by portable capnometer and the arterial PCO2 in spontaneously breathing patients.

Y Takano1, O Sakamoto, C Kiyofuji, K Ito.   

Abstract

An end-tidal CO2 (ETCO2) monitor (capnometer) is used most often as a noninvasive substitute for PaCO2 in anesthesia, anesthetic recovery and intensive care. However, the utility and accuracy of the portable capnometer in spontaneously breathing patients with or without chronic pulmonary diseases has received little recognition. To determine the utility of the portable capnometer in general wards and in in-home care, we examined the correlation between ETCO2 measured by a portable capnometer and simultaneous PaCO2 measured in 41 spontaneously breathing patients. TV-ETCO2 (ETCO2 measured by tidal volume maneuver) was lower than PaCO2 by an average of 9.0 mmHg and VC-ETCO2 (ETCO2 measured by vital capacity maneuver) was lower than PaCO2 by an average of 0.5 mmHg. The mean difference between PaCO2 and VC-ETCO2 was not statistically significant. Regression analysis showed a close correlation between VC-ETCO2 and PaCO2 (r = 0.91, P < 0.0001). Thus,VC-ETCO2 was highly correlated with PaCO2. Furthermore, a close correlation between VC-ETCO2 and PaCO2 was also observed in patients with compromised pulmonary function (r = 0.88, P < 0.0001 in patients with below 70% of FEV(1.0)%; r = 0.89, P < 0.0001 in patients with below 80% of %VC). Our studies show that VC-ETCO2 measured by the portable capnometer gives a reliable pointestimate of PaCO2, and can be useful to evaluate the respiratory condition of spontaneously breathing patients in general wards and in in-home care.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12735663     DOI: 10.1053/rmed.2002.1468

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  19 in total

1.  Capnographic monitoring for carbon dioxide insufflation during endoscopic submucosal dissection: comparison of transcutaneous and end-tidal capnometers [corrected].

Authors:  Ryusaku Kusunoki; Yuji Amano; Takafumi Yuki; Akihiko Oka; Mayumi Okada; Yasumasa Tada; Goichi Uno; Ichiro Moriyama; Norihisa Ishimura; Shunji Ishihara; Yoshikazu Kinoshita
Journal:  Surg Endosc       Date:  2011-09-22       Impact factor: 4.584

2.  BOLD fMRI of visual and somatosensory-motor stimulations in baboons.

Authors:  Hsiao-Ying Wey; Jinqi Li; C Akos Szabó; Peter T Fox; M Michelle Leland; Lisa Jones; Timothy Q Duong
Journal:  Neuroimage       Date:  2010-05-13       Impact factor: 6.556

3.  Can gender differences be evaluated in a rhesus macaque (Macaca mulatta) model of focal cerebral ischemia?

Authors:  Stephanie J Murphy; Jeffrey R Kirsch; Wenri Zhang; Marjorie R Grafe; G Alex West; Gregory J del Zoppo; Richard J Traystman; Patricia D Hum
Journal:  Comp Med       Date:  2008-12       Impact factor: 0.982

4.  Are the local blood oxygen level-dependent (BOLD) signals caused by neural stimulation response dependent on global BOLD signals induced by hypercapnia in the functional MR imaging experiment? Experiments of long-duration hypercapnia and multilevel carbon dioxide concentration.

Authors:  Y J Liu; C J Juan; C Y Chen; C Y Wang; M L Wu; C P Lo; M C Chou; T Y Huang; H Chang; C H Chu; M H Li
Journal:  AJNR Am J Neuroradiol       Date:  2007 Jun-Jul       Impact factor: 3.825

5.  Effects of Stellate Ganglion Blockade on Muscle Blood Flow During Hypercapnia.

Authors:  Tatsuya Ichinohe; Yui Akiike; Natsuki Saito; Masato Koike; Kyotaro Koshika; Nobuyuki Matsuura
Journal:  Anesth Prog       Date:  2020-09-01

6.  Comparison of Simultaneous Capillary Blood Gases and End-Tidal Carbon Dioxide in Mechanically Ventilated Pediatric Patients with Acute Respiratory Failure.

Authors:  Capan Konca; Mehmet Tekin; Fatih Uckardes; Samet Benli; Ahmet Kucuk
Journal:  J Pediatr Intensive Care       Date:  2020-07-20

7.  Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease.

Authors:  Takatoshi Enomoto; Yoshikazu Inoue; Yuichi Adachi; Shunichi Kouno; Yuji Inagaki; Koji Azuma; Kanako Katayama; Naoko Takeuchi; Yoshinobu Matsuda
Journal:  Turk Thorac J       Date:  2021-05

8.  End-tidal CO(2) levels lower in subclinical and overt hypothyroidism than healthy controls; no relationship to thyroid function tests.

Authors:  Khalil Ansarin; Babak Niroomand; Farzad Najafipour; Naser Aghamohammadzadeh; Mitra Niafar; Akbar Sharifi; Mohammadali M Shoja
Journal:  Int J Gen Med       Date:  2011-01-07

Review 9.  State-of-the-art sensor technology in Spain: invasive and non-invasive techniques for monitoring respiratory variables.

Authors:  Christian Domingo; Lluis Blanch; Gaston Murias; Manel Luján
Journal:  Sensors (Basel)       Date:  2010-05-05       Impact factor: 3.576

10.  Assessment of Nocturnal Hypoventilation by Different Methods and Definitions in Children with Neuromuscular Disease: Oxycapnography and Blood Gas Analysis.

Authors:  Yetkin Ayhan; Elif Yuksel Karatoprak; Zeynep Reyhan Onay; Sinem Can Oksay; Saniye Girit
Journal:  Medeni Med J       Date:  2021-06-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.