Literature DB >> 12735572

Valve sparing aortic root replacement for dilatation of the pulmonary autograft and aortic regurgitation after the Ross procedure.

Toru Ishizaka1, Eric J Devaney, Stephen R Ramsburgh, Takaaki Suzuki, Richard G Ohye, Edward L Bove.   

Abstract

BACKGROUND: Aortic insufficiency secondary to progressive dilatation of the pulmonary autograft is being recognized with increasing frequency after the Ross procedure. We reviewed our experience with valve-sparing aortic root replacement concomitant with aortic annuloplasty to assess the effectiveness of this approach.
METHODS: Four patients, aged 8 to 27 years, presented with moderate to severe aortic insufficiency associated with progressive root dilatation from 1 to 8 years after a Ross procedure. All patients had 0 to 1+ aortic insufficiency early after the Ross procedure, with a mean maximal sinus diameter of 37 mm (range 30 to 45 mm). At reoperation the maximum diameter of the root ranged from 45 to 55 mm (mean 50 +/- 4 mm). A valve-sparing aortic root replacement with annular reduction was performed. The annulus was decreased from a mean of 27 mm to 23 mm. For the root replacement, 1 patient underwent a standard root remodeling procedure; in the others, a separate piece of scalloped Dacron (C.R. Bard, Haverhill, PA) graft material was used for each sinus to facilitate optimal exposure.
RESULTS: All 4 patients are in New York Heart Association functional class I at a mean follow-up of 6 months. The most recent echocardiography demonstrated 0 to 1+ aortic insufficiency with good left ventricular function. Histology of the excised pulmonary autograft walls demonstrated severe elastin fragmentation.
CONCLUSIONS: Aortic root remodeling with annular reduction is an effective treatment for aortic root dilatation and aortic insufficiency after the Ross operation. This procedure allows correction of aortic insufficiency and avoids the need for a prosthetic valve and anticoagulation.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12735572     DOI: 10.1016/s0003-4975(02)04904-4

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  Performance of the pulmonary autograft in four infants after the Ross procedure.

Authors:  V L Vida; M Rubino; T Bottio; S Sponga; O Milanesi; G Stellin
Journal:  Pediatr Cardiol       Date:  2005 Nov-Dec       Impact factor: 1.655

Review 2.  Aortic valve replacement in children: Options and outcomes.

Authors:  Bahaaldin Alsoufi
Journal:  J Saudi Heart Assoc       Date:  2013-11-13

Review 3.  Understanding Pulmonary Autograft Remodeling After the Ross Procedure: Stick to the Facts.

Authors:  Lucas Van Hoof; Peter Verbrugghe; Elizabeth A V Jones; Jay D Humphrey; Stefan Janssens; Nele Famaey; Filip Rega
Journal:  Front Cardiovasc Med       Date:  2022-02-09
  3 in total