Literature DB >> 12734163

Blind nasotracheal intubation is facilitated by neutral head position and endotracheal tube cuff inflation in spontaneously breathing patients.

Yung-Tai Chung1, Maw-Sheng Sun, Hung-Shan Wu.   

Abstract

PURPOSE: To evaluate, using an endotracheal tube mounted on a flexible lighted stylet, how the patient's head-neck position and inflation of the endotracheal cuff affect correct alignment of the tube tip with the glottis.
METHODS: Eighty-two patients were enrolled. The course of the endotracheal tube in the pharynx was examined by observing the anterior neck for transillumination in each patient under four different intubating conditions. These were: patient's head on pad (8 cm) with the cuff deflated (HP-deflation group); patient's head on pad with the cuff inflated (HP-inflation group); patient's head on bed with the cuff deflated (HB-deflation group); and patient's head on bed with the cuff inflated (HB-inflation group).
RESULTS: Both a head on bed (neutral) position or endotracheal tube cuff inflation (15 mL of air) significantly increased the frequency of correct alignment of the tip of the endotracheal tube with the glottis. Blind nasotracheal intubation (BNTI) was successful in 69 patients (84%). Lightwand-assisted nasotracheal intubation was required in 11 of the remaining 13 patients (13%) and fibreoptic bronchoscopy-assisted intubation was performed in the last two patients.
CONCLUSION: A neutral position of the head combined with endotracheal tube cuff inflation is recommended for BNTI.

Entities:  

Mesh:

Year:  2003        PMID: 12734163     DOI: 10.1007/BF03021066

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  4 in total

Review 1.  [Methods of airway management in prehospital emergency medicine].

Authors:  W Keul; M Bernhard; A Völkl; R Gust; A Gries
Journal:  Anaesthesist       Date:  2004-10       Impact factor: 1.041

2.  Cuff inflation to aid nasotracheal intubation using the C-MAC videolaryngoscope.

Authors:  H K Baddoo; B J Phillips
Journal:  Ghana Med J       Date:  2011-06

3.  Does C-MAC® video laryngoscope improve the nasotracheal intubating conditions compared to Macintosh direct laryngoscope in paediatric patients posted for tonsillectomy surgeries?

Authors:  Vinuta V Patil; Bala H Subramanya; N Kiranchand; S Bala Bhaskar; Srinivasalu Dammur
Journal:  Indian J Anaesth       Date:  2016-10

4.  A comparison of intubating conditions for nasotracheal intubation with standard direct Macintosh laryngoscope versus C-MAC® video laryngoscope employing cuff inflation technique in adult patients.

Authors:  Sonia Kasaudhan; Madhu Gupta; Kriti Singh; Anas Khan
Journal:  Indian J Anaesth       Date:  2021-09-15
  4 in total