Literature DB >> 12729596

Assessment of cell concentration and viability of isolated hepatocytes using flow cytometry.

Alan J Wigg1, John W Phillips, Loretta Wheatland, Michael N Berry.   

Abstract

The assessment of cell concentration and viability of freshly isolated hepatocyte preparations has been traditionally performed using manual counting with a Neubauer counting chamber and staining for trypan blue exclusion. Despite the simple and rapid nature of this assessment, concerns about the accuracy of these methods exist. Simple flow cytometry techniques which determine cell concentration and viability are available yet surprisingly have not been extensively used or validated with isolated hepatocyte preparations. We therefore investigated the use of flow cytometry using TRUCOUNT Tubes and propidium iodide staining to measure cell concentration and viability of isolated rat hepatocytes in suspension. Analysis using TRUCOUNT Tubes provided more accurate and reproducible measurement of cell concentration than manual cell counting. Hepatocyte viability, assessed using propidium iodide, correlated more closely than did trypan blue exclusion with all indicators of hepatocyte integrity and function measured (lactate dehydrogenase leakage, cytochrome p450 content, cellular ATP concentration, ammonia and lactate removal, urea and albumin synthesis). We conclude that flow cytometry techniques can be used to measure cell concentration and viability of isolated hepatocyte preparations. The techniques are simple, rapid, and more accurate than manual cell counting and trypan blue staining and the results are not affected by protein-containing media.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12729596     DOI: 10.1016/s0003-2697(03)00057-5

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  3 in total

1.  Method to Disassemble Spheroids into Core and Rim for Downstream Applications Such as Flow Cytometry, Comet Assay, Transcriptomics, Proteomics, and Lipidomics.

Authors:  Helle Sedighi Frandsen; Martina Štampar; Joel Mario Vej-Nielsen; Bojana Žegura; Adelina Rogowska-Wrzesinska
Journal:  Methods Mol Biol       Date:  2021

Review 2.  CMOS cell sensors for point-of-care diagnostics.

Authors:  Yekbun Adiguzel; Haluk Kulah
Journal:  Sensors (Basel)       Date:  2012-07-25       Impact factor: 3.576

3.  A non-aggressive, highly efficient, enzymatic method for dissociation of human brain-tumors and brain-tissues to viable single-cells.

Authors:  Ilan Volovitz; Netanel Shapira; Haim Ezer; Aviv Gafni; Merav Lustgarten; Tal Alter; Idan Ben-Horin; Ori Barzilai; Tal Shahar; Andrew Kanner; Itzhak Fried; Igor Veshchev; Rachel Grossman; Zvi Ram
Journal:  BMC Neurosci       Date:  2016-06-01       Impact factor: 3.288

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.