Literature DB >> 12725396

Determination of lead in seawater by flow-injection on-line preconcentration-electrothermal atomic absorption spectrometry after coprecipitation with iron(III) hydroxide.

Junichi Nakajima1, Yoshihiro Hirano, Koichi Oguma.   

Abstract

A flow-injection on-line preconcentration-electrothermal atomic absorption spectrometric (ETAAS) method coupled with a coprecipitation method has been developed for the determination of lead in seawater. The combination of two preconcentration procedures, coprecipitation with iron(II) hydroxide and solid-phase extraction with a lead-selective resin, Pb-Spec, allowed the determination of lead at the ng kg(-1) level. Lead in 250 g of a sample solution was collected by coprecipitation with 10 mg of iron. The precipitate was dissolved in 25 ml of 1 mol l(-1) nitric acid; then, a 4-ml aliquot of the sample solution was introduced into the flow-injection system to preconcentrate and separate lead from iron on a Pb.Spec microcolumn. The sorbed lead was eluted with a 1.0 x 10(-4) mol l(-1) EDTA solution. The 30-microl portion of the eluate corresponding to the highest analyte concentration zone was injected into a graphite furnace. The overall enhancement factor was about 200 for 250 g of the sample. The average and standard deviation of ten blank values obtained were 1.7 ng and 0.38 ng, respectively. The recovery was 93.7 +/- 5.0% for seawater spiked with 20 ng kg(-1) lead. The proposed method is applicable to the analysis of seawater for lead at slightly higher levels.

Entities:  

Year:  2003        PMID: 12725396     DOI: 10.2116/analsci.19.585

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   2.081


  3 in total

1.  Trace lead measurement and online removal of matrix interference in geosamples by ion-exchange coupled with flow injection and hydride generation atomic fluorescence spectrometry.

Authors:  Chun-Hua Tan; Xu-Guang Huang
Journal:  J Autom Methods Manag Chem       Date:  2009-09-06

2.  Thiopental and Phenytoin as Novel Ionophores for Potentiometric Determination of Lead (II) Ions.

Authors:  Nashwa M H Rizk; Samah S Abbas; Salem M Hamza; Yasser M Abd El-Karem
Journal:  Sensors (Basel)       Date:  2009-03-13       Impact factor: 3.576

3.  Ultratrace Determination of Cr(VI) and Pb(II) by Microsample Injection System Flame Atomic Spectroscopy in Drinking Water and Treated and Untreated Industrial Effluents.

Authors:  Jameel Ahmed Baig; Tasneem Gul Kazi; Latif Elci; Hassan Imran Afridi; Muhammad Irfan Khan; Hafiz Muhammad Naseer
Journal:  J Anal Methods Chem       Date:  2013-09-18       Impact factor: 2.193

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.