Literature DB >> 12724882

Detection of speaking with a new respiratory inductive plethysmography system.

Frank H Wilhelm1, Eva M Handke, Walton T Roth.   

Abstract

The LifeShirt system, a garment with integrated sensors connected to a handheld computer, allows recording of a wide variety of clinically important cardiorespiratory data continuously for extended periods outside the laboratory or clinic. The device includes sensors for assessment of physical activity and posture since both can affect physiological activation and need to be controlled. Speaking is another potential confounding factor in the interpretation of physiological data. Auditory speech recording is problematic because it can pick up sources other than the person's voice (external microphone) or is obtrusive (throat microphone). The abdominal and thoracic calibrated respiratory inductive plethysmography (RIP) sensors integrated in the LifeShirt system might be an adequate alternative for detecting speech. In a laboratory experiment we determined respiratory parameters indicative of speech. Eighteen subjects were instructed to sit quietly, write, and speak continuously, for 4 min each. Nine parameters were derived from the RIP signals and averaged over each minute. In addition, nine variability parameters were computed as their coefficients of breath-by-breath variation. Inspiratory/expiratory time (IE-ratio) best distinguished speaking from writing with 98% correct classification at a cutoff criterion of 0.52. This criterion was equally successful in distinguishing speaking from sitting quietly. Discriminant analyses indicated that linear combinations of IE-ratio and a variety of other parameters did not reliably improve classification accuracy across tasks and replications. These results demonstrate the high efficacy of RIP-derived IE-ratio for speech detection and suggest that auditory recording is not necessary for detection of speech in ambulatory assessment.

Entities:  

Mesh:

Year:  2003        PMID: 12724882

Source DB:  PubMed          Journal:  Biomed Sci Instrum        ISSN: 0067-8856


  3 in total

1.  Aroused at Home: Basic Autonomic Regulation during Orthostatic and Physical Activation is Altered in Children with Social Anxiety Disorder.

Authors:  Julia Asbrand; Jens Blechert; Kai Nitschke; Brunna Tuschen-Caffier; Julian Schmitz
Journal:  J Abnorm Child Psychol       Date:  2017-01

2.  Detection of Talking in Respiratory Signals: A Feasibility Study Using Machine Learning and Wearable Textile-Based Sensors.

Authors:  Andreas Ejupi; Carlo Menon
Journal:  Sensors (Basel)       Date:  2018-07-31       Impact factor: 3.576

Review 3.  Telemonitoring with respect to mood disorders and information and communication technologies: overview and presentation of the PSYCHE project.

Authors:  Hervé Javelot; Anne Spadazzi; Luisa Weiner; Sonia Garcia; Claudio Gentili; Markus Kosel; Gilles Bertschy
Journal:  Biomed Res Int       Date:  2014-06-24       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.