Literature DB >> 12724647

Improved detection of inferobasal ischemia during dobutamine echocardiography with doppler tissue imaging.

Marina Leitman1, Stanislav Sidenko, Ruth Wolf, Edgar Sucher, Simha Rosenblatt, Eli Peleg, Ricardo Krakover, Zvi Vered.   

Abstract

OBJECTIVES: The purpose of this study was quantitative evaluation of the inferobasal segment during dobutamine stress echocardiography using Doppler tissue imaging (DTI).
BACKGROUND: Overdiagnosis of myocardial ischemia during dobutamine echocardiography is a common problem. DTI may permit more accurate quantitative diagnosis of ischemia.
METHODS: A total of 50 patients with normal contraction of the inferobasal segment at rest were referred for dobutamine stress echocardiography. All underwent coronary angiography. Systolic and diastolic myocardial velocities were measured from apical 2-chamber view at rest and at the peak of dobutamine infusion.
RESULTS: Stenosis of the right coronary artery >or= 70% was detected in 11 patients. Conventional stress echocardiography was falsely positive in 10.3% and falsely negative in 27.3%. When DTI was combined with conventional stress echocardiography, sensitivity and specificity was 81.8% and 97.4%, respectively.
CONCLUSION: DTI may enhance the diagnosis of inferior ischemia during dobutamine echocardiography and can be added to conventional imaging in the treatment of these patients.

Entities:  

Mesh:

Year:  2003        PMID: 12724647     DOI: 10.1016/s0894-7317(03)00015-4

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  3 in total

1.  Efficacy of post exercise pulsed wave tissue velocity imaging in diagnosing more than 70% coronary artery stenosis.

Authors:  S R Mittal
Journal:  Indian Heart J       Date:  2012-12-26

2.  Left ventricle diastolic function in the patients after coronary arteries bypass graft combined with left ventricle aneurismectomy according to tissue doppler imaging: one year follow-up.

Authors:  Maryna N Dolzhenko; S A Rudenko; S V Potashev; T V Simagina; N N Nosenko; T G Kravchenko
Journal:  Postgrad Med J       Date:  2007-05       Impact factor: 2.401

3.  Tissue Doppler echocardiographic quantification. Comparison to coronary angiography results in Acute Coronary Syndrome patients.

Authors:  Erwan Donal; Pascale Raud-Raynier; Damien Coisne; Joseph Allal; Daniel Herpin
Journal:  Cardiovasc Ultrasound       Date:  2005-04-08       Impact factor: 2.062

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.