Literature DB >> 12723837

The effect of acid primer or conventional acid etching on microleakage in a photoactivated sealant.

Amber O Perry1, Frederick A Rueggeberg.   

Abstract

PURPOSE: The purpose of this study was to examine differences in microleakage in extracted human teeth when placing sealants using conventional acid etching or an acidic primer resin.
METHODS: Three experimental groupings were used: group 1--conventional acid etching with placement of light-cured sealant; group 2--application of acidic primer resin (Prompt-L-Pop) and light curing, followed by sealant placement; group 3--similar to group 2, but acidic primer and sealant were photocured after placement of sealant. Teeth were thermocycled, stained, sectioned and examined for marginal microleakage.
RESULTS: In group 1, 94% of the enamel-sealant interfaces were free of microleakage. For groups 2 and 3, only 28% showed no leakage, with most leakage occurring at both margin and base areas. Nonparametric data analysis indicated acid etching demonstrated significantly lower microleakage than either treatment using the acidic primer resin (P<.001) and that leakage scores in the acidic primer groups were identical (P=.4011).
CONCLUSIONS: Use of this specific acidic resin primer in lieu of conventional acid etching (whether cured prior to or subsequent to sealant placement) demonstrated greater incidence of microleakage and would not be advocated over traditional etching procedures.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12723837

Source DB:  PubMed          Journal:  Pediatr Dent        ISSN: 0164-1263            Impact factor:   1.874


  3 in total

1.  Clinical evaluation of three fissure sealants: 24 month follow-up.

Authors:  W Dukic; D Glavina
Journal:  Eur Arch Paediatr Dent       Date:  2007-09

2.  In vitro evaluation of microleakage under orthodontic brackets using two different laser etching, self etching and acid etching methods.

Authors:  Nihal Hamamci; Atilim Akkurt; Güvenç Başaran
Journal:  Lasers Med Sci       Date:  2009-06-27       Impact factor: 3.161

3.  Microleakage of pit and fissure sealings placed after enamel conditioning with phosphoric acid or with self-etching primers/adhesives.

Authors:  Stefanie Amend; Roland Frankenberger; Christina Boutsiouki; Vanessa Scharrelmann; Julia Winter; Norbert Krämer
Journal:  Clin Exp Dent Res       Date:  2021-04-07
  3 in total