Literature DB >> 12723586

Real-time cerebral monitoring using multichannel near-infrared spectroscopy in total arch replacement.

Yasushige Shingu1, Kazuhiro Myojin, Yoshimitsu Ishibashi, Kouji Ishii, Masakazu Kawasaki, Genbu Yamaura.   

Abstract

Multichannel near-infrared spectroscopy (NIRS) could detect change in the regional cerebral oxygenation by following animated pictures of oxy-hemoglobin (OxyHb), deoxy-hemoglobin (DeoxyHb) and total hemoglobin in operations for three surgical cases of thoracic aortic aneurysm with selective cerebral perfusion (SCP). Simultaneously measured jugular venous oxygen saturation (SjO2) showed no change in parallel to OxyHb or DeoxyHb of NIRS. It was concluded that SjO2 represented the entire rather than the local findings of the cerebral oxidative metabolism. Assessment of the intra cranial oxidative metabolism using a multichannel NIRS provided real-time information about the efficacy of SCP, while SjO2 had a comprehensive limited value. The animation enabled the detection of regional hypoperfusion visually and instantly during SCP. This multichannel NIRS was a new real-time monitoring method and was useful to prevent cerebral neurological complication due to hypoperfusion during SCP.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12723586     DOI: 10.1007/s11748-003-0052-1

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  4 in total

1.  Continuous monitoring of blood oxygen saturation of internal jugular vein as a useful indicator for selective cerebral perfusion during aortic arch replacement.

Authors:  M Kuwabara; N Nakajima; F Yamamoto; T Fujita; S Takeuchi; M Ando; M Adachi; Y Koga
Journal:  J Thorac Cardiovasc Surg       Date:  1992-02       Impact factor: 5.209

2.  Retrograde cerebral perfusion via a superior vena caval cannula for aortic arch aneurysm operations.

Authors:  J S Coselli
Journal:  Ann Thorac Surg       Date:  1994-06       Impact factor: 4.330

3.  Deep hypothermia with circulatory arrest. Determinants of stroke and early mortality in 656 patients.

Authors:  L G Svensson; E S Crawford; K R Hess; J S Coselli; S Raskin; S A Shenaq; H J Safi
Journal:  J Thorac Cardiovasc Surg       Date:  1993-07       Impact factor: 5.209

4.  Prosthetic replacement of the aortic arch.

Authors:  R B Griepp; E B Stinson; J F Hollingsworth; D Buehler
Journal:  J Thorac Cardiovasc Surg       Date:  1975-12       Impact factor: 5.209

  4 in total
  2 in total

1.  Real-time imaging of human brain function by near-infrared spectroscopy using an adaptive general linear model.

Authors:  A Farras Abdelnour; Theodore Huppert
Journal:  Neuroimage       Date:  2009-02-03       Impact factor: 6.556

2.  Correction of motion artifacts and serial correlations for real-time functional near-infrared spectroscopy.

Authors:  Jeffrey W Barker; Andrea L Rosso; Patrick J Sparto; Theodore J Huppert
Journal:  Neurophotonics       Date:  2016-05-23       Impact factor: 3.593

  2 in total