Literature DB >> 12723582

Off-pump multivessel revascularization: efficacy of suction type of coronary stabilizer.

Hitoshi Hirose1, Atsushi Amano, Akihito Takahashi, Naoko Nagano.   

Abstract

OBJECTIVE: Off-pump coronary artery bypass grafting (CABG) has come into widespread use with the availability adequate coronary stabilization devices. We studied the efficacy of second-generation coronary stabilization devices (suction device) comparing to the first-generation device (compression device).
METHODS: We prospectively analyzed consecutive patients who underwent isolated off-pump CABG via a midline sternotomy at Shin-Tokyo Hospital Group between July 1, 1996, and August 31, 2000, comparing perioperative, and follow-up data in the group using a suction device (group S) to that in the group using a compression device (group C).
RESULTS: Preoperative risk factors were identical between the two groups, with the exception of a higher incidence of three vessel disease in group S. Complete revascularization increased from 47.3% in group C to 88.1% in group S, and the number of distal anastomoses from 2.1 +/- 0.6 in group C to 2.9 +/- 0.9 in group S. Revascularization of the circumflex artery was achieved in 21.7% of group S patients, which was significantly higher than that in group C (2.2%). Postoperative recovery, mortality, and morbidity did not differ significantly between groups. Calculated event-free rates at 2 years was 88.7% in group C and 92.0% in group S (p = NS).
CONCLUSIONS: Anastomosis to the posterior wall of the heart using the suction device is safe. An increased number of distal anastomoses may reduce the occurrence of cardiac events related to incomplete revascularization.

Entities:  

Mesh:

Year:  2003        PMID: 12723582     DOI: 10.1007/s11748-003-0048-x

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  12 in total

1.  A simplified method of stabilization and hemostasis for minimally invasive coronary artery bypass.

Authors:  X M Mueller; H T Tevaearai; L K von Segesser; F Stumpe
Journal:  Ann Thorac Surg       Date:  1999-06       Impact factor: 4.330

2.  Off-pump coronary artery bypass: early results.

Authors:  H Hirose; A Amano; S Yoshida; A Takahashi; N Nagano
Journal:  Ann Thorac Cardiovasc Surg       Date:  2000-04       Impact factor: 1.520

3.  Off-pump coronary bypass grafting: how to use the Octopus Tissue Stabilizer.

Authors:  E W Jansen; J R Lahpor; C Borst; P F Gründeman; J J Bredée
Journal:  Ann Thorac Surg       Date:  1998-08       Impact factor: 4.330

4.  Less invasive arterial CABG on a beating heart.

Authors:  V A Subramanian
Journal:  Ann Thorac Surg       Date:  1997-06       Impact factor: 4.330

5.  Off-pump coronary artery bypass. Mid-term results.

Authors:  A Amano; H Hirose; A Takahashi; N Nagano
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2001-01

6.  Coronary artery revascularisation without extracorporeal circulation. Indications and results.

Authors:  T A Folliguet; F Laborde; J Temkine; A Dibie; P Bourel; P Y Etienne; M C Malergue
Journal:  Eur J Cardiothorac Surg       Date:  1997-05       Impact factor: 4.191

7.  Natural killer cell activity after open-heart surgery.

Authors:  P Ryhänen; K Huttunen; J Ilonen
Journal:  Acta Anaesthesiol Scand       Date:  1984-10       Impact factor: 2.105

8.  Adverse cerebral outcomes after coronary bypass surgery. Multicenter Study of Perioperative Ischemia Research Group and the Ischemia Research and Education Foundation Investigators.

Authors:  G W Roach; M Kanchuger; C M Mangano; M Newman; N Nussmeier; R Wolman; A Aggarwal; K Marschall; S H Graham; C Ley
Journal:  N Engl J Med       Date:  1996-12-19       Impact factor: 91.245

9.  Coronary artery bypass without cardiopulmonary bypass: analysis of short-term and mid-term outcome in 220 patients.

Authors:  Y Moshkovitz; A Lusky; R Mohr
Journal:  J Thorac Cardiovasc Surg       Date:  1995-10       Impact factor: 5.209

10.  Impaired B lymphocyte function during open-heart surgery. Effects of anaesthesia and surgery.

Authors:  J Eskola; M Salo; M K Viljanen; O Ruuskanen
Journal:  Br J Anaesth       Date:  1984-04       Impact factor: 9.166

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.