Vessel size measurements in angiograms: manual measurements.

Kenneth R Hoffmann1, Jacek Dmochowski, Daryl P Nazareth, László Miskolczi, Balazs Nemes, Anant Gopal, Zhou Wang, Stephen Rudin, Daniel R Bednarek.   

Abstract

Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical practice, choosing to indicate the edges of vessels and catheters to determine sizes and calibrate magnifications, i.e., manual measurements. Thus, we undertook an investigation of the accuracy and precision of vessel sizes calculated from manually indicated edges of vessels. Manual measurements were performed by three neuroradiologists and three physicists. Vessel sizes ranged from 0.1-3.0 mm in simulation studies and 0.3-6.4 mm in phantom studies. Simulation resolution functions had full-widths-at-half-maximum (FWHM) ranging from 0.0 to 0.5 mm. Phantom studies were performed with 4.5 in., 6 in., 9 in., and 12 in. image intensifier modes, magnification factor = 1, with and without zooming. The accuracy and reproducibility of the measurements ranged from 0.1 to 0.2 mm, depending on vessel size, resolution, and pixel size, and zoom. These results indicate that manual measurements may have accuracies comparable to automated techniques for vessels with sizes greater than 1 mm, but that automated techniques which take into account the resolution function should be used for vessels with sizes smaller than 1 mm.

Mesh:

Year:  2003        PMID: 12722820     DOI: 10.1118/1.1562491

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Experimental comparison of cone beam CT (CBCT) reconstruction and multi-view reconstruction (MVR) for microangiography (MA) detector system.

Authors:  Vikas Patel; Andrew T Kuhls; Peter B Noël; Alan Walczak; Ciprian N Ionita; Ravishankar Chityala; Rekha Tranquebar; Hussain S Rangwala; Snehal S Kasodekar; Kenneth R Hoffmann; Daniel Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006

2.  New microangiography system development providing improved small vessel imaging, increased contrast to noise ratios, and multi-view 3D reconstructions.

Authors:  Andrew T Kuhls; Vikas Patel; Ciprian Ionita; Peter B Noël; Alan M Walczak; Hussain S Rangwala; Kenneth R Hoffmann; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.