B0 images obtained from diffusion-weighted echo planar sequences for the detection of intracerebral bleeds.

W W M Lam1, N M C So, K S Wong, T Rainer.   

Abstract

BACKGROUND AND
PURPOSE: To evaluate the accuracy of B0 echo planar imaging (EPI) sequences for the detection of intracerebral bleeds.
METHODS: One hundred patients with acute strokes had magnetic resonance imaging and computed tomography (CT) examinations performed within 48 hours after the onset of symptoms. The detectability of intracerebral bleeds by the B0 EPI sequences was assessed. The results were compared to the gradient echo (GRE) sequence and CT brain examinations. The results of the GRE sequences were used as the gold standard.
RESULTS: The B0 EPI sequences detected 11 out of 11 acute, intracerebral hematomas; 6 out of 8 acute hemorrhagic strokes; 2 out of 2 acute, intraventricular hemorrhages; 8 out of 8 old hemorrhagic infarcts; 1 out of 1 subarachnoid hemorrhages; and 11 out of 22 patients with microbleeds. For the detection of acute, intracerebral hematomas and acute, hemorrhagic infarcts, B0 EPI sequences had a sensitivity of 89.5%, a specificity of 100%, and an accuracy of 98%. CT had a sensitivity of 57.9%, a specificity of 100%, and an accuracy of 92%. B0 EPI sequences did not miss any acute or chronic hemorrhages detected by CT examinations.
CONCLUSIONS: B0 EPI sequences could not replace GRE images for the detection of both acute and chronic hemorrhages. Their sensitivity for the detection of acute and chronic blood products, however, was comparable, if not superior, to that of CT examinations.

Entities:  

Mesh:

Year:  2003        PMID: 12722491

Source DB:  PubMed          Journal:  J Neuroimaging        ISSN: 1051-2284            Impact factor:   2.486


  3 in total

1.  Measuring elevated microvascular permeability and predicting hemorrhagic transformation in acute ischemic stroke using first-pass dynamic perfusion CT imaging.

Authors:  K Lin; K S Kazmi; M Law; J Babb; N Peccerelli; B K Pramanik
Journal:  AJNR Am J Neuroradiol       Date:  2007-08       Impact factor: 3.825

Review 2.  Use of perfusion imaging and other imaging techniques to assess risks/benefits of acute stroke interventions.

Authors:  Jason Tarpley; Dan Franc; Aaron P Tansy; David S Liebeskind
Journal:  Curr Atheroscler Rep       Date:  2013-07       Impact factor: 5.113

3.  Optimal brain MRI protocol for new neurological complaint.

Authors:  William A Mehan; R Gilberto González; Bradley R Buchbinder; John W Chen; William A Copen; Rajiv Gupta; Joshua A Hirsch; George J Hunter; Scott Hunter; Jason M Johnson; Hillary R Kelly; Mykol Larvie; Michael H Lev; Stuart R Pomerantz; Otto Rapalino; Sandra Rincon; Javier M Romero; Pamela W Schaefer; Vinil Shah
Journal:  PLoS One       Date:  2014-10-24       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.