Literature DB >> 12721348

Mechano-acoustic diagnosis of cartilage degeneration and repair.

Mikko S Laasanen1, Juha Töyräs, Anna I Vasara, Mika M Hyttinen, Simo Saarakkala, Jani Hirvonen, Jukka S Jurvelin, Ilkka Kiviranta.   

Abstract

BACKGROUND: The combined use of high-frequency ultrasound and mechanical indentation has been suggested for the evaluation of cartilage integrity. In this study, we investigated the usefulness of high-resolution B-mode ultrasound imaging and quantitative mechanical measurements for the diagnosis of cartilage degeneration and for monitoring tissue-healing after autologous chondrocyte transplantation.
METHODS: In the first study, osteochondral samples (n = 32) were obtained from the lateral facet of a bovine patella, and the samples were visually classified as intact (n = 13) or degenerated (n = 19) and were graded with use of the Mankin scoring system. Samples were imaged with use of a 20-MHz ultrasound instrument, and the dynamic modulus (Edyn) of cartilage was determined in unconfined compression with use of a high-resolution materials tester. In the second study, cartilage chondrocytes were harvested from the low-weight-bearing area of six-month-old porcine knee joints and cultured. A month later, a cartilage lesion was created on the facet of the femoral trochlea and was repaired with use of the autologous chondrocyte transplantation technique (n = 10). Three months later, to estimate cartilage Edyn, the repair tissue, the adjacent cartilage, and the sham-operated contralateral joint cartilage (control) were analyzed in situ with an arthroscopic indentation instrument. Subsequently, the same sites were imaged with ultrasound.
RESULTS: All visually degenerated bovine samples (mean Mankin score = 4) and five visually normal samples (Mankin score = 1) showed reduced Edyn (<2.1 MPa) as compared with histologically normal cartilage (Edyn = 13.8 +/- 3.2 MPa, Mankin score = 0). Cartilage stiffness, as shown by the indenter force, was lower (0.6 +/- 0.3 N, p < 0.05, Wilcoxon's signed-rank test) in the porcine tissue repaired with autologous chondrocyte transplantation than it was in the adjacent (1.6 +/- 0.1 N) or the control (1.9 +/- 0.4 N) tissue. The superficial and internal structure of the degenerated and repaired tissue, including the subchondral erosion at the repair site, was sensitively demonstrated by the ultrasound imaging.
CONCLUSIONS: Measurement of cartilage Edyn is an objective method with which to follow changes in the mechanical integrity of cartilage. B-mode ultrasound imaging offers detailed information on the structural properties of cartilage and subchondral bone.

Entities:  

Mesh:

Year:  2003        PMID: 12721348     DOI: 10.2106/00004623-200300002-00010

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  6 in total

1.  Ultrasound properties of articular cartilage immediately after osteochondral grafting surgery: in cases of traumatic cartilage lesions and osteonecrosis.

Authors:  Hiroshi Kuroki; Yasuaki Nakagawa; Koji Mori; Masahiko Kobayashi; Shinichiro Nakamura; Kohei Nishitani; Takaaki Shirai; Takashi Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-08-07       Impact factor: 4.342

Review 2.  Nondestructive Techniques to Evaluate the Characteristics and Development of Engineered Cartilage.

Authors:  Joseph M Mansour; Zhenghong Lee; Jean F Welter
Journal:  Ann Biomed Eng       Date:  2016-01-27       Impact factor: 3.934

3.  Biomechanical Changes of Repair Tissue after Autologous Chondrocyte Implantation at Long-Term Follow-Up.

Authors:  Teemu Paatela; Anna Vasara; Heikki Nurmi; Hannu Kautiainen; Jukka S Jurvelin; Ilkka Kiviranta
Journal:  Cartilage       Date:  2020-05-23       Impact factor: 3.117

4.  Acoustic stiffness and change in plug cartilage over time after autologous osteochondral grafting: correlation between ultrasound signal intensity and histological score in a rabbit model.

Authors:  Hiroshi Kuroki; Yasuaki Nakagawa; Koji Mori; Mao Ohba; Takashi Suzuki; Yasuyuki Mizuno; Keiji Ando; Makoto Takenaka; Ken Ikeuchi; Takashi Nakamura
Journal:  Arthritis Res Ther       Date:  2004-09-14       Impact factor: 5.156

5.  A superficial hyperechoic band in human articular cartilage on ultrasonography with histological correlation: preliminary observations.

Authors:  Tae Sun Han; Kyu-Sung Kwack; Sunghoon Park; Byoung-Hyun Min; Seung-Hyun Yoon; Hyun Young Lee; Kyi Beom Lee
Journal:  Ultrasonography       Date:  2014-12-28

6.  Ultrasound properties of articular cartilage in the tibio-femoral joint in knee osteoarthritis: relation to clinical assessment (International Cartilage Repair Society grade).

Authors:  Hiroshi Kuroki; Yasuaki Nakagawa; Koji Mori; Masahiko Kobayashi; Ko Yasura; Yukihiro Okamoto; Takashi Suzuki; Kohei Nishitani; Takashi Nakamura
Journal:  Arthritis Res Ther       Date:  2008-07-13       Impact factor: 5.156

  6 in total