Literature DB >> 12721182

Accuracy of sperm-cervical mucus penetration tests in evaluating sperm motility in semen: a systematic quantitative review.

Bolarinde Ola1, Masoud Afnan, Spyros Papaioannou, Khaldoun Sharif, Lars Björndahl, Aravinthan Coomarasamy.   

Abstract

BACKGROUND: Our objective was to determine the accuracy of in-vitro sperm penetration into cervical mucus or substitutes in evaluating sperm motility in semen.
METHODS: This was a systematic quantitative review of test accuracy studies. The Cochrane library (2000:4), Medline (1966-2001), Embase (1988-2001) and SciSearch (1981-2001) were searched, in addition to manual searches of conference papers and bibliographies of known primary and review articles. Primary studies measuring in-vitro sperm penetration into cervical mucus, or substitutes (i.e. sperm-mucus penetration test, SMPT) and comparing results with sperm motility in semen were included.
RESULTS: There were 18 primary diagnostic studies published in 17 papers, involving a total of 2580 samples. Fourteen primary diagnostic tests used vanguard distance as diagnostic criteria (SMPT(vd)) and the pooled likelihood ratio (LR) for positive (LR+) and negative (LR-) tests were 2.29 (1.82-2.87) and 0.52 (0.44-0.63) respectively. Four studies used diagnostic criteria based directly or indirectly on swim-up sperm count per high power field (SMPT(sc)) instead. Their pooled LR+ and LR- were 5.24 (3.36-8.18) and 0.15 (0.06-0.39) respectively.
CONCLUSIONS: SMPT(vd) has a low accuracy in the evaluation of sperm motility in semen. However, SMPT(sc) was found to be more accurate. This method of using sperm concentration, instead of vanguard distance, as diagnostic criteria of in-vitro SMPT has potential as a useful laboratory-based sperm function test.

Mesh:

Year:  2003        PMID: 12721182     DOI: 10.1093/humrep/deg209

Source DB:  PubMed          Journal:  Hum Reprod        ISSN: 0268-1161            Impact factor:   6.918


  3 in total

1.  The cytoplasmic droplet may be indicative of sperm motility and normal spermiogenesis.

Authors:  Hui Xu; Shui-Qiao Yuan; Zhi-Hong Zheng; Wei Yan
Journal:  Asian J Androl       Date:  2013-06-17       Impact factor: 3.285

2.  The effects of reproductive hormones on the physical properties of cervicovaginal fluid.

Authors:  Catherine A Chappell; Lisa C Rohan; Bernard J Moncla; Lin Wang; Leslie A Meyn; Katherine Bunge; Sharon L Hillier
Journal:  Am J Obstet Gynecol       Date:  2014-03-21       Impact factor: 8.661

Review 3.  Effects of nonoxynol-9 (N-9) on sperm functions: systematic review and meta-analysis.

Authors:  Murong Xu; Mingpeng Zhao; Raymond Hang Wun Li; Zhixiu Lin; Jacqueline Pui Wah Chung; Tin Chiu Li; Tin-Lap Lee; David Yiu Leung Chan
Journal:  Reprod Fertil       Date:  2022-02-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.