Literature DB >> 12720344

Characterization of platinum nanoparticle-embedded carbon film electrode and its detection of hydrogen peroxide.

Tianyan You1, Osamu Niwa, Masato Tomita, Shigeru Hirono.   

Abstract

A method for the highly sensitive determination of acetylcholine (ACh) and choline (Ch) that employs a graphite-like carbon film electrode containing 6.5% platinum (Pt) nanoparticles was developed for use as a detector in microbore liquid chromatography (LC) with a postcolumn enzyme reactor. The film electrode was prepared by RF cosputtering carbon and Pt, which requires only a one-step formation process. This method can control the Pt content of the film at a relatively low deposition temperature (below 200 degrees C). The average size of the Pt nanoparticles was 2.5 nm. The film electrode showed excellent electrocatalytic activity, high sensitivity, and negligible baseline drift when detecting hydrogen peroxide. The electrode was modified with glucose oxidase and responded rapidly to glucose with a much more stable baseline current than at a Pt bulk electrode based sensor. Therefore, it is appropriate to employ the electrode to detect trace amounts of biomolecules, such as neurotransmitters and hormones combined with various oxidase enzymes. We used the electrode as a detector for microbore LC and observed a low detection limit of 2.5 and 2.3 fmol (10-microL injection) for ACh and Ch, respectively, which is approximately 1 order of magnitude lower than that of a Pt bulk electrode.

Entities:  

Year:  2003        PMID: 12720344     DOI: 10.1021/ac026337w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Ceramic-based microelectrode arrays: recording surface characteristics and topographical analysis.

Authors:  Pooja M Talauliker; David A Price; Jason J Burmeister; Silpa Nagari; Jorge E Quintero; Francois Pomerleau; Peter Huettl; J Todd Hastings; Greg A Gerhardt
Journal:  J Neurosci Methods       Date:  2011-04-12       Impact factor: 2.390

2.  Simple Fabrication of Flexible Biosensor Arrays Using Direct Writing for Multianalyte Measurement from Human Astrocytes.

Authors:  James K Nolan; Tran N H Nguyen; Khanh Vy H Le; Luke E DeLong; Hyowon Lee
Journal:  SLAS Technol       Date:  2019-11-26       Impact factor: 3.047

3.  Edge-plane microwire electrodes for highly sensitive H₂O₂ and glucose detection.

Authors:  Liangliang Qiang; Santhisagar Vaddiraju; Dipesh Patel; Fotios Papadimitrakopoulos
Journal:  Biosens Bioelectron       Date:  2011-02-18       Impact factor: 10.618

4.  Highly sensitive and reusable Pt-black microfluidic electrodes for long-term electrochemical sensing.

Authors:  Liangliang Qiang; Santhisagar Vaddiraju; James F Rusling; Fotios Papadimitrakopoulos
Journal:  Biosens Bioelectron       Date:  2010-07-23       Impact factor: 10.618

5.  Real-Time Measurement of Cellobiose and Glucose Formation during Enzymatic Biomass Hydrolysis.

Authors:  Hucheng Chang; Lena Wohlschlager; Florian Csarman; Adrian Ruff; Wolfgang Schuhmann; Stefan Scheiblbrandner; Roland Ludwig
Journal:  Anal Chem       Date:  2021-05-20       Impact factor: 6.986

6.  One-pot synthesis of poly (3,4-ethylenedioxythiophene)-Pt nanoparticle composite and its application to electrochemical H2O2 sensor.

Authors:  Li-Chi Chang; Huan-Nung Wu; Chia-Yu Lin; Yi-Hsuan Lai; Chih-Wei Hu; Kuo-Chuan Ho
Journal:  Nanoscale Res Lett       Date:  2012-06-20       Impact factor: 4.703

  6 in total