| Literature DB >> 12718358 |
Leigh G Griffiths1, Martin Sullivan, Turlough O'Neill, Stewart W J Reid.
Abstract
The tympanic bullae of 20 previously healthy cadaver animals were randomly filled with sterile saline or air. The heads were positioned using tape ties and a rostrocaudal open mouth radiograph taken. The resulting radiographs were assessed by a blinded ECVDI diplomate, with each tympanic bulla being recorded as being either air or fluid filled. Ultrasound examination of the bullae was performed, by a blinded assessor, using a B-mode 5 mHz sector probe (Sonotron-VingMed Sound A/S, PO Box 141, N3191, Horten, Norway) operating at 3 mHz. Each bulla was recorded as being either air or fluid filled. Results of radiography and ultrasonography were each compared to the actual status of the bulla in a chi square analysis. Sensitivity of radiography was 80%, with specificity of 65%. Ultrasonographic sensitivity was 100% and specificity 100%. Ultrasonography may in future provide a cheap, noninvasive, rapid and widely available method for diagnosing otitis media in clinical cases.Entities:
Mesh:
Year: 2003 PMID: 12718358 DOI: 10.1111/j.1740-8261.2003.tb01273.x
Source DB: PubMed Journal: Vet Radiol Ultrasound ISSN: 1058-8183 Impact factor: 1.363