Literature DB >> 12714751

Comparison of intravenous coronary angiography using synchrotron radiation with selective coronary angiography.

W-R Dix1, W Kupper, T Dill, C W Hamm, H Job, M Lohmann, B Reime, R Ventura.   

Abstract

Intravenous coronary angiography with synchrotron radiation is a novel and minimally invasive technique for coronary imaging. At the Hamburger Synchrotronstrahlungslabor HASYLAB at DESY, a dedicated angiography system has been developed, which has been shown to provide detailed images of coronary artery segments. For each scan, two monochromatic X-ray images below and above the K-edge of iodine were recorded simultaneously. The two images were subtracted logarithmically to produce a maximal contrast enhancement of the iodine. To date, the procedure has been carried out on 379 outpatients. No complications occurred during or after the angiographic procedure, and hospitalization was not required in any subject. The acceptance by patient is extremely high. Five outside reviewers, blinded as to the clinical data or prior angiographic interpretation, reviewed the images for the presence or absence of 70% or more occlusion of a vessel. They reached a sensitivity of 79% and a specificity of 99%. The study has demonstrated that the synchrotron method has satisfactory sensitivity and very high specificity for severe stenoses. The new method has several advantages over magnetic resonance imaging (MRI), electron beam computed tomography (EBCT), and multi-slice computed tomography (MSCT). Neither vascular calcification (CT) nor the presence of metal stents (MRI) impairs the evaluation of perfusion of segments of the coronary arteries. Furthermore, the spatial resolution is three or four times higher using synchrotron angiography, and problems due to respiratory motion are eliminated.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12714751     DOI: 10.1107/s0909049503001973

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  6 in total

1.  Synchrotron radiation in radiology: radiology techniques based on synchrotron sources.

Authors:  Reto Meuli; Yeukuang Hwu; Jung Ho Je; Giorgio Margaritondo
Journal:  Eur Radiol       Date:  2004-07-31       Impact factor: 5.315

2.  K-edge subtraction imaging for iodine and calcium separation at a compact synchrotron x-ray source.

Authors:  Stephanie Kulpe; Martin Dierolf; Eva-Maria Braig; Benedikt Günther; Klaus Achterhold; Bernhard Gleich; Julia Herzen; Ernst Rummeny; Franz Pfeiffer; Daniela Pfeiffer
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-21

3.  Synchrotron radiation computed tomography versus conventional computed tomography for assessment of four types of stent grafts used for endovascular treatment of thoracic and abdominal aortic aneurysms.

Authors:  Zhonghua Sun; Curtise K C Ng; Cláudia Sá Dos Reis
Journal:  Quant Imaging Med Surg       Date:  2018-07

4.  Development of an X-ray real-time stereo imaging technique using synchrotron radiation.

Authors:  Masato Hoshino; Kentaro Uesugi; James Pearson; Takashi Sonobe; Mikiyasu Shirai; Naoto Yagi
Journal:  J Synchrotron Radiat       Date:  2011-05-24       Impact factor: 2.616

5.  A novel intravital method to evaluate cerebral vasospasm in rat models of subarachnoid hemorrhage: a study with synchrotron radiation angiography.

Authors:  Jun Cai; Yuhao Sun; Falei Yuan; Lujia Chen; Chuan He; Yuhai Bao; Zuoquan Chen; Meiqing Lou; Weiliang Xia; Guo-Yuan Yang; Feng Ling
Journal:  PLoS One       Date:  2012-03-12       Impact factor: 3.240

6.  K-edge Subtraction Computed Tomography with a Compact Synchrotron X-ray Source.

Authors:  Stephanie Kulpe; Martin Dierolf; Benedikt Günther; Madleen Busse; Klaus Achterhold; Bernhard Gleich; Julia Herzen; Ernst Rummeny; Franz Pfeiffer; Daniela Pfeiffer
Journal:  Sci Rep       Date:  2019-09-16       Impact factor: 4.379

  6 in total