Literature DB >> 12713132

Removal of molecular weight fractions of COD and phenolic compounds in an integrated treatment of olive oil mill effluents.

M Beccari1, G Carucci, A M Lanz, M Majone, M Petrangeli Papini.   

Abstract

Previous works (Beccari et al. 1999b; Beccari et al. 2001a; Beccari et al. 2001b) on the anaerobic treatment of olive oil mill effluents (OME) have shown: (a) a pre-treatment based on the addition of Ca(OH)2 and bentonite was able to remove lipids (i.e. the most inhibiting substances present in OME) almost quantitatively; (b) the mixture OME-Ca(OH)2-bentonite, fed to a methanogenic reactor without providing an intermediate phase separation, gave way to high biogas production even at very low dilution ratios; (c) the effluent from the methanogenic reactor still contained significant concentrations of residual phenolic compounds (i.e. the most biorecalcitrant substances present in OME). Consequently, this paper was aimed at evaluating the fate of the phenolic fractions with different molecular weights during the sequence of operations (adsorption on bentonite, methanogenic digestion, activated sludge post-treatment). The results show that a very high percentage (above 80%) of the phenolic fraction below 500 D is removed by the methanogenic process whereas the phenolic fractions above 1,000 D are significantly adsorbed on bentonite; the 8-day activated sludge post-treatment allows an additional removal of about 40% of total filtered phenolic compounds. The complete sequence of treatments was able to remove more than the 96% of the phenolic fraction below 500 D (i.e. the most toxic fraction towards plant germination). Preliminary respirometric tests show low level of inhibition exerted by the effluent from the methanogenic reactor on aerobic activated sludges taken from full-scale municipal wastewater plants.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12713132     DOI: 10.1023/a:1022818229452

Source DB:  PubMed          Journal:  Biodegradation        ISSN: 0923-9820            Impact factor:   3.909


  2 in total

1.  Potential of ultrafiltration for organic matter removal in the polymer industry effluent based on particle size distribution analysis.

Authors:  Serdar Doğruel; Emine Ubay Çokgör; Orhan Ince; Seval Sözen; Derin Orhon
Journal:  Environ Sci Pollut Res Int       Date:  2012-05-15       Impact factor: 4.223

2.  Performances and microbial features of an aerobic packed-bed biofilm reactor developed to post-treat an olive mill effluent from an anaerobic GAC reactor.

Authors:  Lorenzo Bertin; Maria Chiara Colao; Maurizio Ruzzi; Leonardo Marchetti; Fabio Fava
Journal:  Microb Cell Fact       Date:  2006-04-05       Impact factor: 5.328

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.