Literature DB >> 12712367

Late complication of open inguinal hernia repair: small bowel obstruction caused by intraperitoneal mesh migration.

Roberto Ferrone1, Pier Carlo Scarone, Gianni Natalini.   

Abstract

We describe a case of small bowel obstruction due to prosthetic mesh migration. A 67-year-old male, who had undergone prosthetic repair of inguinal hernia 3 years before, was admitted for a mechanical small bowel obstruction. Laparotomy revealed the penultimate ileal loop choked by an adhesion drawing it towards a polypropylene mesh, firmly attached to the parietal peritoneum of the inguinal region. The intestinal loop was released; the mesh was embedded deep with continuous whip suture after folding the parietal peritoneum. The patient was dismissed on the 11th postoperative day surgically healed. The "tension-free" technique is undoubtedly the gold standard for hernia repair. However, it is not free of complications, mostly due to technical errors, of which the surgeon must be aware, both when he is responsible for correcting defects in the wall, as well as when he has to face an occlusion in a patient who has undergone plastic surgery for inguinal hernia.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12712367     DOI: 10.1007/s10029-003-0129-x

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  9 in total

1.  [A rare complication caused by prosthetic mesh in inguinal hernioplasty. A case report].

Authors:  G Panzironi; M De Vargas Macciucca; F Ricci; P Angelini; F De Cristofaro
Journal:  Radiol Med       Date:  2000-12       Impact factor: 3.469

2.  Small bowel obstruction resulting from mesh plug migration after open inguinal hernia repair.

Authors:  J A Chuback; R S Singh; C Sills; L S Dick
Journal:  Surgery       Date:  2000-04       Impact factor: 3.982

3.  [Intestinal obstruction by migration of wire mesh into the intestinal lumen following hernia repair].

Authors:  E Deligné; S Faucompret; C Louis; J P Arigon; Y Bréda
Journal:  Ann Chir       Date:  2001-07

4.  Complications associated with the plug-and-patch method of inguinal herniorrhaphy.

Authors:  K A LeBlanc
Journal:  Hernia       Date:  2001-09       Impact factor: 4.739

5.  Intestinal obstruction following transabdominal pre-peritoneal laparoscopic inguinal hernia repair: comment.

Authors:  D C O'Riordan; L F Horgan
Journal:  Aust N Z J Surg       Date:  1998-01

6.  Mesh migration following laparoscopic inguinal hernia repair.

Authors:  R H Hume; J Bour
Journal:  J Laparoendosc Surg       Date:  1996-10

7.  Migration of wire mesh into the intestinal lumen causing an intestinal obstruction 30 years after repair of a ventral hernia.

Authors:  J Majeski
Journal:  South Med J       Date:  1998-05       Impact factor: 0.954

8.  Mesh plug migration into scrotum: a new complication of hernia repair.

Authors:  R A Dieter
Journal:  Int Surg       Date:  1999 Jan-Mar

9.  The mesh plug technique for recurrent groin herniorrhaphy: a nine-year experience of 407 repairs.

Authors:  I M Rutkow; A W Robbins
Journal:  Surgery       Date:  1998-11       Impact factor: 3.982

  9 in total
  18 in total

1.  A case of ventral hernia mesh migration with splenosis mimicking a gastric mass.

Authors:  Gavin A Falk; John Ryan Means; Auora Dawn Pryor
Journal:  BMJ Case Rep       Date:  2009-09-28

Review 2.  Mesh migration following repair of inguinal hernia: a case report and review of literature.

Authors:  A Agrawal; R Avill
Journal:  Hernia       Date:  2005-10-29       Impact factor: 4.739

3.  Late intestinal fistula formation after incisional hernia using intraperitoneal mesh.

Authors:  V Ott; Y Groebli; R Schneider
Journal:  Hernia       Date:  2004-12-23       Impact factor: 4.739

4.  Marlex mesh mimicking an adnexal malignancy.

Authors:  M A Rettenmaier; S Heinemann; H Truong; J P Micha; J V Brown; B H Goldstein
Journal:  Hernia       Date:  2008-09-16       Impact factor: 4.739

5.  Mesh migration following abdominal hernia repair: a comprehensive review.

Authors:  H B Cunningham; J J Weis; L R Taveras; S Huerta
Journal:  Hernia       Date:  2019-01-30       Impact factor: 4.739

6.  Rare late mesh complications following inguinal prolene hernia system hernioplasty: report of three cases.

Authors:  Marinko Zuvela; Zoran Krivokapic; Danijel Galun; Velimir Markovic
Journal:  Surg Today       Date:  2012-05-19       Impact factor: 2.549

7.  Intraluminal migration of mesh following incisional hernia repair.

Authors:  E Steinhagen; S Khaitov; R M Steinhagen
Journal:  Hernia       Date:  2010-07-24       Impact factor: 4.739

8.  Bowel complications after prolene hernia system (PHS) repair: a case report and review of the literature.

Authors:  D J Lo; K Y Bilimoria; C M Pugh
Journal:  Hernia       Date:  2008-01-31       Impact factor: 4.739

9.  A rare case of acute intestinal obstruction due to bowel entrapment in migrated onlay polypropylene mesh.

Authors:  S K Tiwari; Pawanindra Lal
Journal:  Ann R Coll Surg Engl       Date:  2014-10       Impact factor: 1.891

10.  International guidelines for groin hernia management.

Authors: 
Journal:  Hernia       Date:  2018-01-12       Impact factor: 4.739

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.