BACKGROUND: There are several therapeutic strategies for restoring the anterior column of the vertebral body after trauma, tumor and infection. We present a multicenter study with a new distractable titanium implant for vertebral body replacement.
METHODS: Prospective documentation was collected of the first 126 patients treated with Synex during the 1st year of the clinical course. There was an evaluation of surgical indication, classification, localisation of the lesion, operative details, complications, and clinical course.
RESULTS: A total of 70 men and 56 women (average age 46.9 years) underwent surgery for vertebral fracture, correction of posttraumatic kyphosis, infection, vertebral tumor and metastasis, and other diseases such as ankylosing spondylitis. Synex was used in open and minimally invasive surgery. In almost every case, an additional anteriorly or posteriorly stabilizing implant was used. Anterior fusion was performed with cement in tumors and autologous bone in fractures. Mono- and multisegmental lesions in the thoracic and lumbar spine were treated.
CONCLUSIONS: The Synex implant is very easy to manage and is suitable for many indications such as vertebral fracture, correction of posttraumatic kyphosis, infection, vertebral tumor/metastasis, and other diseases. The vertebral body replacement can be used for defects of different sizes with the option of in situ distraction. No cases of implant failure, dislocation, or other implant-related complication have been observed. As a consequence of this prospective series, an additional implant size has been added, and the distraction device (spreading forceps) has been modified for more powerful spreading.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12712359     DOI: 10.1007/s00402-003-0486-z

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  9 in total

Review 1.  [Vertebral body replacement in spine surgery].

Authors:  F Kandziora; K J Schnake; C K Klostermann; N P Haas
Journal:  Unfallchirurg       Date:  2004-05       Impact factor: 1.000

2.  [Bone grafts endoscopically applied to the spine Ergebnisse der anterioren Fusion und therapeutische Konsequenzen].

Authors:  D Briem; J Windolf; W Lehmann; P G C Begemann; N M Meenen; J M Rueger; W Linhart
Journal:  Unfallchirurg       Date:  2004-12       Impact factor: 1.000

3.  [An improved vertebral body replacement for the thoracolumbar spine. A biomechanical in vitro test on human lumbar vertebral bodies].

Authors:  M Reinhold; W Schmölz; F Canto; D Krappinger; M Blauth; C Knop
Journal:  Unfallchirurg       Date:  2007-04       Impact factor: 1.000

4.  [Titanium vertebral body replacement of adjustable size. A prospective clinical trial].

Authors:  U Lange; S Edeling; C Knop; L Bastian; C Krettek; M Blauth
Journal:  Unfallchirurg       Date:  2006-09       Impact factor: 1.000

5.  Initial experience with the use of an expandable titanium cage as a vertebral body replacement in patients with tumors of the spinal column: a report of 95 patients.

Authors:  Ashwin Viswanathan; Muhammad M Abd-El-Barr; Egon Doppenberg; Dima Suki; Ziya Gokaslan; Ehud Mendel; Ganesh Rao; Laurence D Rhines
Journal:  Eur Spine J       Date:  2011-06-18       Impact factor: 3.134

6.  Anterior vertebral body replacement with a titanium implant of adjustable height: a prospective clinical study.

Authors:  Uta Lange; Sebastian Edeling; Christian Knop; Leonard Bastian; Michael Oeser; Christian Krettek; Michael Blauth
Journal:  Eur Spine J       Date:  2006-05-13       Impact factor: 3.134

7.  Internet based multicenter study for thoracolumbar injuries: a new concept and preliminary results.

Authors:  Christian Knop; Maximilian Reinhold; Christoph Roeder; Lukas Staub; Rene Schmid; Rudolf Beisse; Volker Bühren; Michael Blauth
Journal:  Eur Spine J       Date:  2006-05-20       Impact factor: 3.134

8.  Combined posterior-anterior stabilisation of thoracolumbar injuries utilising a vertebral body replacing implant.

Authors:  Christian Knop; T Kranabetter; M Reinhold; M Blauth
Journal:  Eur Spine J       Date:  2009-04-09       Impact factor: 3.134

9.  Spinal loads during cycling on an ergometer.

Authors:  Antonius Rohlmann; Thomas Zander; Friedmar Graichen; Hendrik Schmidt; Georg Bergmann
Journal:  PLoS One       Date:  2014-04-17       Impact factor: 3.240

  9 in total