Literature DB >> 12711379

The sources of laser Doppler blood-flow signals recorded from human teeth.

S Soo-ampon1, N Vongsavan, M Soo-ampon, S Chuckpaiwong, B Matthews.   

Abstract

Records of pulpal blood flow obtained from human teeth with a laser Doppler flowmeter include a very large component derived from periodontal and other tissues outside the pulp, but this contamination can be reduced by covering the surrounding tissues with opaque rubber dam. The present experiments were carried out to determine what proportion of the signal obtained with this dam in place is derived from non-pulpal tissues. Recordings were made from 22 healthy, intact upper incisors in 14 individuals (aged 22-40 years) with and without dam under the following conditions: from the intact teeth, after local anaesthesia (LA) and the preparation of a deep cavity in the incisal third of the labial surface of the tooth, and after removal of the pulp and arrest of bleeding. In some cases, a reading was also made after replacing the pulp in the pulp cavity. The rubber dam reduced significantly (P<0.05) the mean blood flow reading from the intact teeth by 73%, from 6.98 arbitrary perfusion units (PU) (+/-1.30 S.D., n=22) to 1.92+/-1.50 PU. After LA and cavity preparation, the mean signal with dam was 1.45+/-0.61 PU (n=16). This fell significantly by 76% to 0.35+/-0.19 PU (n=16) when the pulp was removed but not replaced, and by 43% to 0.98+/-0.36 PU (n=14) when the pulp was removed and replaced in the pulp cavity. The latter condition is thought to reproduce most closely the scattering of light in an intact tooth. The results confirm previous findings that up to 80% of the laser Doppler blood-flow signal recorded from an intact human tooth without rubber dam is of non-pulpal origin. They also show that only approximately 43% of the signal recorded with an opaque rubber dam is from pulp.

Entities:  

Mesh:

Year:  2003        PMID: 12711379     DOI: 10.1016/s0003-9969(03)00011-6

Source DB:  PubMed          Journal:  Arch Oral Biol        ISSN: 0003-9969            Impact factor:   2.633


  6 in total

1.  Pulpal blood flow changes in abutment teeth of removable partial dentures.

Authors:  Göknil Ergün Kunt; Deniz Kökçü; Gözlem Ceylan; Nergiz Yilmaz; Ahmet Umut Güler
Journal:  Bosn J Basic Med Sci       Date:  2009-11       Impact factor: 3.363

2.  The use of laser Doppler flowmetry in paediatric dentistry.

Authors:  H Roeykens; R De Moor
Journal:  Eur Arch Paediatr Dent       Date:  2011-04

3.  Diurnal variations and pulpal status: is there a need for FFT besides LDF?

Authors:  Herman J J Roeykens; Roeland J G De Moor
Journal:  Lasers Med Sci       Date:  2018-06-13       Impact factor: 3.161

4.  Dental pulp testing: a review.

Authors:  Eugene Chen; Paul V Abbott
Journal:  Int J Dent       Date:  2009-11-12

5.  The effect of exercise on pulpal and gingival blood flow in physically active and inactive subjects as assessed by laser Doppler.

Authors:  Ec Lobo; Smt Nguyen; Ma Pogrel
Journal:  Open Dent J       Date:  2012-03-16

6.  Laser Doppler Blood-Flow Signals from Human Teeth during an Alignment and Leveling Movement Using a Superelastic Archwire.

Authors:  Alvaro Wagner Rodrigues Salles; Adriana Mirian Cotrim Salles; Gessé Eduardo Calvo Nogueira
Journal:  ISRN Dent       Date:  2013-09-19
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.