Literature DB >> 12710754

Role of the microgap between implant and abutment: a retrospective histologic evaluation in monkeys.

Adriano Piattelli1, Giuseppe Vrespa, Giovanna Petrone, Giovanna Iezzi, Susanna Annibali, Antonio Scarano.   

Abstract

BACKGROUND: It has been hypothesized that a certain width of the peri-implant mucosa is required to enable a proper epithelial-connective tissue attachment and, if this soft tissue dimension is not adequate, bone resorption will occur to ensure the establishment of attachment with an appropriate biological width. The reason for the accelerated bone loss around submerged 2-piece implants in the first year after the restoration is not known, but one possibility is that the gap between components plays a role in this process. Recent studies have shown that for all 2-part implants, the bone crest level changes appeared dependent on the location of the microgap.
METHODS: The aim of the present study was a retrospective histologic evaluation in monkeys of the bone response to implants inserted 1 to 2 mm above the alveolar crest (group 1, 15 implants), at the level of the alveolar crest (group 2, 12 implants), or 1 to 1.5 mm below the alveolar crest (group 3, 13 implants). These implants had been early loaded, immediately loaded, and inserted immediately postextraction.
RESULTS: In group 1, a 0.13 +/- 0.12 mm bone increase in a coronal direction was seen. In group 2, a 2.1 +/- 0.29 mm vertical bone loss was present. In group 3, a mean 3.6 +/- 0.46 mm vertical bone loss extending in an apical direction was observed. Statistically significant differences were observed between all 3 groups.
CONCLUSIONS: Our results confirm data published previously that if the microgap was moved coronally away from the alveolar crest, less bone loss would occur and if the microgap was moved apical to the alveolar crest, greater amounts of bone resorption were present. This remodeling is not dependent on early and immediate loading of the implants or on immediate postextraction insertion.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12710754     DOI: 10.1902/jop.2003.74.3.346

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  27 in total

Review 1.  Bone level changes around platform switching and platform matching implants: a systematic review with meta-analysis.

Authors:  M DI Girolamo; R Calcaterra; R DI Gianfilippo; C Arcuri; L Baggi
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

2.  Bacterial diversity of periodontal and implant-related sites detected by the DNA Checkerboard method.

Authors:  C do Nascimento; N Monesi; I Y Ito; J P M Issa; R F de Albuquerque Junior
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-04-30       Impact factor: 3.267

3.  Implant-abutment leaking of replace conical connection nobel biocare® implant system. An in vitro study of the microbiological penetration from external environment to implant-abutment space.

Authors:  E El Haddad; A B Giannì; G E Mancini; F Cura; F Carinci
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

4.  Prosthetic Abutment Height is a Key Factor in Peri-implant Marginal Bone Loss.

Authors:  P Galindo-Moreno; A León-Cano; I Ortega-Oller; A Monje; F Suárez; F ÓValle; S Spinato; A Catena
Journal:  J Dent Res       Date:  2014-03-12       Impact factor: 6.116

5.  Effect of different localizations of microgap on clinical parameters and inflammatory cytokines in peri-implant crevicular fluid: a prospective comparative study.

Authors:  A Duygu Boynueğri; Mehmet Yalim; Seçil Karakoca Nemli; B Imge Ergüder; Pelin Gökalp
Journal:  Clin Oral Investig       Date:  2011-01-07       Impact factor: 3.573

6.  Analysis of the intraimplant microflora of two-piece dental implants.

Authors:  Sönke Harder; Rainer Podschun; Livia Grancicova; Christian Mehl; Matthias Kern
Journal:  Clin Oral Investig       Date:  2012-09-08       Impact factor: 3.573

7.  Sealing Capability and SEM Observation of the Implant-Abutment Interface.

Authors:  Fabio C Lorenzoni; Paulo G Coelho; Gerson Bonfante; Ricardo M Carvalho; Nelson R F A Silva; Marcelo Suzuki; Thelma Lopes Silva; Estevam A Bonfante
Journal:  Int J Dent       Date:  2011-07-02

8.  Platform switching on wide-diameter external hex implants: a finite element analysis.

Authors:  Stefano Sivolella; Riccardo Guazzo; Eriberto Bressan; Mario Berengo; Edoardo Stellini
Journal:  J Clin Exp Dent       Date:  2013-04-01

9.  Peri-implant crestal bone loss: a putative mechanism.

Authors:  Yuko Ujiie; Reynaldo Todescan; John E Davies
Journal:  Int J Dent       Date:  2012-10-02

10.  Osseointegrated implants placed at supracrestal level may harbour higher counts of A. gerencseriae and S. constellatus - a randomized, controlled pilot study.

Authors:  Mariana Ribeiro de Moraes Rego; Marcelo Ferreira Torres; Luiz Carlos Santiago; Ronaldo Lira-Junior; Eduardo José Veras Lourenço; Daniel de Moraes Telles; Carlos Marcelo Figueredo
Journal:  J Oral Microbiol       Date:  2015-10-23       Impact factor: 5.474

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.