Literature DB >> 12710311

Catheter ablation of chronic atrial fibrillation with noncontact mapping: are continuous linear lesions associated with ablation success?

Karlheinz Seidl1, Harald Schwacke, Ralf Zahn, Monika Rameken, Axel Drögemüller, Jochen Senges.   

Abstract

Catheter-based, right and left atrial compartmentalization procedure was evaluated using a noncontact mapping (NCM) system. Its usefulness to identify and close discontinuities in linear lesions in both atria was evaluated. The impact of linear lesion continuity on ablation success of chronic AF was also investigated. Nineteen patients with symptomatic, drug refractory chronic AF were studied. Right atrial ablation with three predefined lines was attempted in all patients. In 18 patients, left atrial ablation was performed with four linear lesions. During a follow-up of 12 +/- 3 months, 6 of 19 patients remained in sinus rhythm (SR) without antiarrhythmic agents (AAs). In addition, four patients were maintained in SR with AA. Thirteen of 14 patients with gaps identified during off-line analysis had recurrence of AF. Only one patient with a gap was free of recurrence without AAs. In the remaining five patients without recurrence of AF, no gap was observed during off-line analysis. In all four patients who were free of AF with additional treatment of AAs, two gaps had been identified. In the remaining nine patients with chronic AF recurrence, a mean of 4.9 gaps were identified. Excluding the initial learning period (first five patients) the success rate increased to 43% (6/14 patients) without and to 71% (10/14 patients) with AA. NCM identifies discontinuities in lines of ablation. Successful ablation of chronic AF is associated with continuity of linear lesions and good clinical technique demands a vigilant search for and closure of every gap.

Entities:  

Mesh:

Year:  2003        PMID: 12710311     DOI: 10.1046/j.1460-9592.2003.00091.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  Catheter ablation of permanent atrial fibrillation: medium term results.

Authors:  M J Earley; D J R Abrams; A D Staniforth; S C Sporton; R J Schilling
Journal:  Heart       Date:  2005-08-23       Impact factor: 5.994

2.  Visualizing ablation gaps in vitro using a deflectable fiber optic endocardial visualization catheter.

Authors:  Afraaz R Irani; Bryant Lin; Christian Eversull; Henry H Hsia; Paul C Zei; Paul J Wang; Amin Al-Ahmad
Journal:  J Interv Card Electrophysiol       Date:  2009-01-16       Impact factor: 1.900

3.  Pulmonary vein ablation for idiopathic atrial fibrillation: six month outcome of first procedure in 100 consecutive patients.

Authors:  J P Bourke; A Dunuwille; D O'Donnell; S Jamieson; S S Furniss
Journal:  Heart       Date:  2005-01       Impact factor: 5.994

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.