Literature DB >> 12707151

Electron paramagnetic resonance assessment of brain tissue oxygen tension in anesthetized rats.

Huagang Hou1, Oleg Y Grinberg, Satoshi Taie, Steve Leichtweis, Minoru Miyake, Stalina Grinberg, Haiyi Xie, Marie Csete, Harold M Swartz.   

Abstract

UNLABELLED: The adequacy of cerebral tissue oxygenation (PtO(2)) is a central therapeutic end point in critically ill and anesthetized patients. Clinically, PtO(2) is currently measured indirectly, based on measurements of cerebrovascular oxygenation using near infrared spectroscopy and experimentally, using positron emission tomographic scanning. Recent developments in electron paramagnetic resonance (EPR) oximetry facilitate accurate, sensitive, and repeated measurements of PtO(2). EPR is similar to nuclear magnetic resonance but detects paramagnetic species. Because these species are not abundant in brain (or other tissues) in vivo, oxygen-responsive paramagnetic lithium phthalocyanine crystals implanted into the cerebral cortex are used for the measurement of oxygen. The line widths of the EPR spectra of these materials are linear functions of PtO(2). We used EPR oximetry in anesthetized rats to study the patterns of PtO(2) during exposure to various inhaled and injected general anesthetics and to varying levels of inspired oxygen. Rats anesthetized with 2.0 minimum alveolar anesthetic concentration isoflurane maintained the largest PtO(2) (38.0 +/- 4.5 mm Hg) and rats anesthetized with ketamine/xylazine had the smallest PtO(2) (3.5 +/- 0.3 mm Hg) at a fraction of inspired oxygen (FIO(2)) of 0.21, P < 0.05. The maximal PtO(2) achieved under ketamine/xylazine anesthesia with FIO(2) of 1.0 was 8.8 +/- 0.3 mm Hg, whereas PtO(2) measured during isoflurane anesthesia with FIO(2) of 1.0 was 56.3 +/- 1.7 mm Hg (P < 0.05). These data highlight the experimental utility of EPR in measuring PtO(2) during anesthesia and serve as a foundation for further study of PtO(2) in response to physiologic perturbations and therapeutic interventions directed at preventing cerebral ischemia. IMPLICATIONS: Using in vivo electron paramagnetic resonance oximetry, we studied the patterns of cerebral tissue oxygenation (PtO(2)) during exposure to various inhaled and injected general anesthetics, and to varying levels of inspired oxygen. These data show that inhaled anesthetics result in larger levels of PtO(2) in the brain than do several injectable anesthetics. The results highlight the experimental utility of electron paramagnetic resonance in measuring PtO(2) during anesthesia and serve as a foundation for further study of PtO(2) in response to physiologic perturbations and therapeutic interventions directed at preventing cerebral ischemia.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12707151     DOI: 10.1213/01.ane.0000055648.41152.63

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  12 in total

1.  In vivo observation of intracellular oximetry in perfluorocarbon-labeled glioma cells and chemotherapeutic response in the CNS using fluorine-19 MRI.

Authors:  Deepak K K Kadayakkara; Jelena M Janjic; Lisa K Pusateri; Won-Bin Young; Eric T Ahrens
Journal:  Magn Reson Med       Date:  2010-09-21       Impact factor: 4.668

Review 2.  Repetitive tissue pO2 measurements by electron paramagnetic resonance oximetry: current status and future potential for experimental and clinical studies.

Authors:  Nadeem Khan; Benjamin B Williams; Huagang Hou; Hongbin Li; Harold M Swartz
Journal:  Antioxid Redox Signal       Date:  2007-08       Impact factor: 8.401

3.  Bladder tissue oxygen tension monitoring in pigs subjected to a range of cardiorespiratory and pharmacological challenges.

Authors:  Alex Dyson; Florian Simon; Andrea Seifritz; Olga Zimmerling; José Matallo; Enrico Calzia; Peter Radermacher; Mervyn Singer
Journal:  Intensive Care Med       Date:  2012-10-11       Impact factor: 17.440

4.  A method for measuring brain partial pressure of oxygen in unanesthetized unrestrained subjects: the effect of acute and chronic hypoxia on brain tissue PO(2).

Authors:  E Ortiz-Prado; Siraj Natah; Sathyanarayanan Srinivasan; Jeff F Dunn
Journal:  J Neurosci Methods       Date:  2010-09-15       Impact factor: 2.390

5.  Quantitative tissue oxygen measurement in multiple organs using 19F MRI in a rat model.

Authors:  Siyuan Liu; Sameer J Shah; Lisa J Wilmes; John Feiner; Vikram D Kodibagkar; Michael F Wendland; Ralph P Mason; Nola Hylton; Harriet W Hopf; Mark D Rollins
Journal:  Magn Reson Med       Date:  2011-06-17       Impact factor: 4.668

6.  CNS hypoxia is more pronounced in murine cerebral than noncerebral malaria and is reversed by erythropoietin.

Authors:  Casper Hempel; Valery Combes; Nicholas Henry Hunt; Jørgen Anders Lindholm Kurtzhals; Georges Emile Raymond Grau
Journal:  Am J Pathol       Date:  2011-08-18       Impact factor: 4.307

7.  The impact of inspired oxygen concentration on tissue oxygenation during progressive haemorrhage.

Authors:  Alex Dyson; Ray Stidwill; Val Taylor; Mervyn Singer
Journal:  Intensive Care Med       Date:  2009-07-18       Impact factor: 17.440

8.  Urinary trypsin inhibitor ameliorates renal tissue oxygenation after ischemic reperfusion in rats.

Authors:  Satoshi Taie; Masaaki Ueki; Kosuke Chujo; Takehiko Asaga; Yasuyuki Iwanaga; Junichiro Ono; Nobuhiro Maekawa
Journal:  J Anesth       Date:  2008-05-25       Impact factor: 2.078

9.  Application of Electron Paramagnetic Resonance (EPR) Oximetry to Monitor Oxygen in Wounds in Diabetic Models.

Authors:  Céline M Desmet; Aurore Lafosse; Sophie Vériter; Paolo E Porporato; Pierre Sonveaux; Denis Dufrane; Philippe Levêque; Bernard Gallez
Journal:  PLoS One       Date:  2015-12-14       Impact factor: 3.240

10.  In vivo intracellular oxygen dynamics in murine brain glioma and immunotherapeutic response of cytotoxic T cells observed by fluorine-19 magnetic resonance imaging.

Authors:  Jia Zhong; Masashi Sakaki; Hideho Okada; Eric T Ahrens
Journal:  PLoS One       Date:  2013-05-08       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.