Literature DB >> 12706606

Evolution in impedance at the electrode-skin interface of two types of surface EMG electrodes during long-term recordings.

D J Hewson1, J-Y Hogrel, Y Langeron, J Duchêne.   

Abstract

The evolution in impedance at the electrode-skin interface of Beckman and Red Dot electrodes was assessed during long-term recordings. Impedance was measured between each pair of electrodes, arranged in a bipolar configuration on tibialis anterior (n=13). A waveform constructed of sinusoids of known frequencies, evenly distributed on a log scale from 1-16,384 Hz, was applied through the electrodes, and the result recorded by a DAQ system. SEMG signals were recorded at 1000 Hz during isometric dorsiflexion contractions of 30 s, performed every 15 min for 2 h. Impedance data were acquired at 65,536 Hz immediately before and after SEMG recordings. Large individual differences in impedance levels were observed at low frequencies. At high frequencies, impedance values depended only on the electrode type. Impedance decreased steadily with time for Beckman electrodes (p < 0.05), but did not decrease significantly for Red Dot electrodes. The magnitude of the reduction over time varied widely between individuals, and was related to the initial impedance values. The impedance-bandwidth product remained constant for each electrode type (95% confidence intervals 146.2-148.2 and 126.1-127.8 for Beckman and Red Dot electrodes respectively). When skin impedance is electrically modelled with a simple network containing a resistor and a capacitor, the capacitance varies with the properties of the electrode used, whereas resistance is dependent on the subject. Furthermore, the EMG spectrum is unaffected by impedance provided skin preparation is sufficient to reduce the impedance below 55 komega.

Entities:  

Mesh:

Year:  2003        PMID: 12706606     DOI: 10.1016/s1050-6411(02)00097-4

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  15 in total

1.  Sixty-four channel wearable acquisition system for long-term surface electromyogram recording with electrode arrays.

Authors:  M Pozzo; A Bottin; R Ferrabone; R Merletti
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

2.  Estimation of elbow flexion force during isometric muscle contraction from mechanomyography and electromyography.

Authors:  Wonkeun Youn; Jung Kim
Journal:  Med Biol Eng Comput       Date:  2010-06-04       Impact factor: 2.602

3.  On-line signal quality estimation of multichannel surface electromyograms.

Authors:  C Grönlund; K Roeleveld; A Holtermann; J S Karlsson
Journal:  Med Biol Eng Comput       Date:  2005-05       Impact factor: 2.602

4.  Muscular activity level during pedalling is not affected by crank inertial load.

Authors:  S Duc; V Villerius; W Bertucci; J N Pernin; F Grappe
Journal:  Eur J Appl Physiol       Date:  2005-07-20       Impact factor: 3.078

5.  Neuromuscular adaptations to 8-week strength training: isotonic versus isokinetic mode.

Authors:  Anthony Remaud; Christophe Cornu; Arnaud Guével
Journal:  Eur J Appl Physiol       Date:  2009-09-16       Impact factor: 3.078

6.  Preparation and characterization of a novel sprayable hydrogel for skin preparation to record ECG and other biopotentials.

Authors:  Sunil Tej Boppudi; Suliman Belal; Sitaramanjaneya Reddy Guntur
Journal:  Biomed Eng Lett       Date:  2020-07-29

7.  A methodologic approach for the comparison between dynamic contractions: influences on the neuromuscular system.

Authors:  Anthony Remaud; Christophe Cornu; Arnaud Guével
Journal:  J Athl Train       Date:  2005 Oct-Dec       Impact factor: 2.860

8.  MXene-infused bioelectronic interfaces for multiscale electrophysiology and stimulation.

Authors:  Nicolette Driscoll; Brian Erickson; Brendan B Murphy; Andrew G Richardson; Gregory Robbins; Nicholas V Apollo; Georgios Mentzelopoulos; Tyler Mathis; Kanit Hantanasirisakul; Puneet Bagga; Sarah E Gullbrand; Matthew Sergison; Ravinder Reddy; John A Wolf; H Isaac Chen; Timothy H Lucas; Timothy R Dillingham; Kathryn A Davis; Yury Gogotsi; John D Medaglia; Flavia Vitale
Journal:  Sci Transl Med       Date:  2021-09-22       Impact factor: 19.319

9.  Towards defining biomarkers to evaluate concussions using virtual reality and a moving platform (BioVRSea).

Authors:  Deborah Jacob; Ingunn S Unnsteinsdóttir Kristensen; Romain Aubonnet; Marco Recenti; Leandro Donisi; Carlo Ricciardi; Halldór Á R Svansson; Sólveig Agnarsdóttir; Andrea Colacino; María K Jónsdóttir; Hafrún Kristjánsdóttir; Helga Á Sigurjónsdóttir; Mario Cesarelli; Lára Ósk Eggertsdóttir Claessen; Mahmoud Hassan; Hannes Petersen; Paolo Gargiulo
Journal:  Sci Rep       Date:  2022-05-30       Impact factor: 4.996

10.  A gel-free Ti3C2Tx-based electrode array for high-density, high-resolution surface electromyography.

Authors:  Brendan B Murphy; Patrick J Mulcahey; Nicolette Driscoll; Andrew G Richardson; Gregory T Robbins; Nicholas V Apollo; Kathleen Maleski; Timothy H Lucas; Yury Gogotsi; Timothy Dillingham; Flavia Vitale
Journal:  Adv Mater Technol       Date:  2020-06-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.