Literature DB >> 12706597

Evaluation of a high throughput toxicity biosensor and comparison with a Daphnia magna bioassay.

Byoung Chan Kim1, Kyeong Seo Park, Sang Don Kim, Man Bock Gu.   

Abstract

A high throughput toxicity biosensor has been designed and constructed using recombinant Escherichia coli cells, containing stress specific promoters (recA, fabA, or katG) or constitutive promoters (lac) fused to luciferase genes originating from Vibrio fisheri. These genetically engineered cells were immobilized in 96 well plates. By optimizing cell immobilization conditions and the strains' response specificity to toxic chemicals, bioluminescent outputs decreased or increased dose-dependently upon adding test chemicals. However, to date the toxicity data obtained using this biosensor have not been compared with the results of other toxicity tests. Phenolics were chosen to evaluate the correlation between the LD50 and the EC50 (GC2) or EC120 (DPD2540) of Daphnia magna and E. coli, respectively. Toxicity data obtained from constitutive strains by bioluminescent level decrements were compared with the results from D. magna as a standard. LD50 values were used as parameters of D. magna toxicity and EC50 of EC120 values were used for the immobilized biosensor. In the DPD2540 test, phenolics, membrane damaging toxic chemicals, for testing immobilized stress specific bacterial strains trigger dose-dependant bioluminescence increase within specific concentration. Although the stress specific responsiveness from the strains could not be compared with D. magna's LD50 values, these responses offer additional information, such as upon the mode of toxic action in the sample, in addition to the cellular toxicity results as indicated by the EC50. This novel high throughput toxicity biosensor can be implemented to investigate the toxicity of any other soluble materials, and can be used as a standardization tool for the evaluation of toxicity.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12706597     DOI: 10.1016/s0956-5663(03)00027-7

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  A multi-channel continuous water toxicity monitoring system: its evaluation and application to water discharged from a power plant.

Authors:  Byoung Chan Kim; Man Bock Gu
Journal:  Environ Monit Assess       Date:  2005-10       Impact factor: 2.513

2.  Assessment of Organophosphate and Carbamate Pesticide Residues in Cigarette Tobacco with a Novel Cell Biosensor.

Authors:  Sophie Mavrikou; Kelly Flampouri; Georgia Moschopoulou; Olga Mangana; Alexandros Michaelides; Spiridon Kintzios
Journal:  Sensors (Basel)       Date:  2008-04-23       Impact factor: 3.576