Literature DB >> 12706195

Sensorless freehand 3-D ultrasound using regression of the echo intensity.

Richard W Prager1, Andrew H Gee, Graham M Treece, Charlotte J C Cash, Laurence H Berman.   

Abstract

In freehand 3-D ultrasound (US), a position sensor is attached to the probe of a 2-D US machine. The resulting 3-D data permit flexible visualisation and more accurate volume measurement than can be achieved using 2-D B-scans alone; however, the use of the position sensor can be inconvenient for the clinician. The objective is, thus, to replace the sensor with a technique for estimating the probe trajectory based on the B-scan images, themselves. One such technique exists, based on decorrelation algorithms. This paper presents an alternative approach based on linear regression of the echo-envelope intensity signal. A probabilistic analysis of the speckle characteristics of the US signal leads to a linear model, on which the regression algorithm is based. The gradient parameter of this model is shown to be directly related to probe motion. The viability of the new approach is demonstrated through simulations and in vitro and in vivo experiments.

Mesh:

Year:  2003        PMID: 12706195     DOI: 10.1016/s0301-5629(02)00703-2

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  Handheld real-time volumetric imaging of the spine: technology development.

Authors:  Mohamed Tiouririne; Sarah Nguyen; John A Hossack; Kevin Owen; F William Mauldin
Journal:  J Med Eng Technol       Date:  2014-03

2.  Trackerless panoramic optoacoustic imaging: a first feasibility evaluation.

Authors:  Suhanyaa Nitkunanantharajah; Christoph Hennersperger; Xose Luis Dean-Ben; Daniel Razansky; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-15       Impact factor: 2.924

3.  Registration of 3D freehand ultrasound to a bone model for orthopedic procedures of the forearm.

Authors:  Matija Ciganovic; Firat Ozdemir; Fabien Pean; Philipp Fuernstahl; Christine Tanner; Orcun Goksel
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-04-05       Impact factor: 2.924

4.  A freehand ultrasound elastography system with tracking for in vivo applications.

Authors:  Pezhman Foroughi; Hyun-Jae Kang; Daniel A Carnegie; Mark G van Vledder; Michael A Choti; Gregory D Hager; Emad M Boctor
Journal:  Ultrasound Med Biol       Date:  2012-12-17       Impact factor: 2.998

5.  Cross-correlation-based image acquisition technique for manually-scanned optical coherence tomography.

Authors:  Adeel Ahmad; Steven G Adie; Eric J Chaney; Utkarsh Sharma; Stephen A Boppart
Journal:  Opt Express       Date:  2009-05-11       Impact factor: 3.894

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.